then click the <Next> button.
6. The message “Move To Center Position of Calibration Tool. To Move, Click
[Next].” appears. appears in the message window. Click the <Next> button to
move the head assembly to the calibration tool position on the ANC.
7. The message “Calibration is Prepared. To Calibrate, Click [Next]” appears. At
this time, At this time select the Fly Cam1 in the <Target Camera> combo box
and,click the <Light…> button and adjust the brightness of the light in the
‘Light Control’ dialog box so that the fiducial mark on the CNT20 nozzle that
is seen in the ‘SMVision’ window can be seen clearly. Then click the <Next>
button.
8. The calibration is performed automatically. If it is completed, the calibration
result is displayed as shown in the following figure.
9. For Head #2 ~ Head #6, perform calibration in the same manner as it was
performed for Head #1.
10. If the calibration procedure is completed for all heads normally, the result is
displayed as shown in the following figure.
The measurement result can be confirmed in the R Axis dialog box.
The reference values for the calibration of the R-Axis Offset is as follows.
Real Max(Min): The Max.(Min.) offset between command value and
calibration value
Head1~Head6 : -0.500 ~ 0.500(deg)
Err Max(Min) The Max.(Min.) offset between compensation value and
calibration value
Head1~Head6 : -0.200 ~ 0.200(deg)
"Memo