The reference values for the calibration of the Fiducial Camera is as follows. Fiducial Camera (FOV 12) ScaleX:23.0~27.0( μ m/pixel) ScaleY : 23.0~27.0 ( μ m/pixel) " Memo

in the message box. Click the <Next> button to move the fiducial camera
to the position for the ANC of Fiducial Mark.
3. The message “Calibration is Prepared. To Calibrate, Click [Next]” appears.
At this time, click the <Light…> button and adjust the brightness of the
light in the ‘Light Control’ dialog box so that the fiducial mark that is seen
in the ‘SMVision’ window can be seen clearly. Then click the <Next>
button.
4. The calibration is performed automatically. If it is completed, the
calibration result is displayed as shown in the following figure. Click the
<Update> button to apply the new calibration value.

The reference values for the calibration of the Fiducial Camera is as follows.
Fiducial Camera (FOV 12)
ScaleX:23.0~27.0(μm/pixel)
ScaleY: 23.0~27.0 (μm/pixel)
"Memo

1.2.4. Common XY Calibration
A process to coincide the coordinates of two Gantries. If it is not done correctly,
there will be an offset between Gantry 1 and Gantry2, which will not only affect
placement precision but also cause collision of gantries.
Figure 1-2.”Gantry-to-Gantry Common XY’ dialogbox
<Automatic Next> checkbox
Select this check box and click the <Next> button. Then the process that
matches the coordinate systems between gantries is performed automatically.
<Manual> checkbox
Move the gantry to the designated position by using the teaching box and
perform the process that matches the coordinate systems between gantries
manually.
<Test only> check box
When calibration is done after selecting this, the result is displayed but not
saved. Consequently, it is possible to check the changes made in the current
machine compare to the previous data.
<Device> combo box
Select the Fiducial camera to be moved.
<Move> button
Move the fiducial camera of the selected gantry.
Warning
Operation error caused by unauthorized or untrained
personnel or insufficient checking before calibration could
severely damage the machine
or the set up data, or it could cause personal injury of the
operator or the worker near the machine.
Before carrying out calibration, check the item to be
calibrated and check if there is any worker near the
machine.
And calibration must be carried out by an authorized and
trained user only.