SM411F_Service Manual.pdf - 第64页

13. After finishing the teaching, click th e <Update> button to apply the changed value. F3_Ref# F3_Ref#

100%1 / 245
11. When teaching on the fiducial marks of the selected station is finished, perform
teaching on the fiducial marks of the other stations in the same way.
12. .Perform steps #2 ~ #12 for each station according to the following order:
StationF1 -> StationF2 -> StationR2 -> StationF3.
F2_Ref#
F1_Ref# F1_Ref#
13. After finishing the teaching, click the <Update> button to apply the changed
value.
F3_Ref# F3_Ref#
1.2.6. X-XY Compensation
This is performed to compensate the XY error that occurs while moving the X axis.
If the thermal mapping and gantry mapping have already been enabled, disable the
mapping by force to perform the X-XY compensation.
Caution
X-XY compensation is performed at the factory before the
machine is shipped. An exclusive calibration tool is needed
to perform this calibration.
In general cases, skip this calibration process and perform
the next calibration process.
Figure 1-5. "X-XY Compensation" dialogbox
Mode Option button
Select the mode in which this process is to be performed.
<Calibration> Option button
Perform the X-XY compensation in the calibration mode and reflect the
result.
<Measure> Option button
Perform the X-XY compensation in the measurement mode and do not
reflect the result. It is selected to measure the error for the Y axis.
<Gantry> combo box
Gantry1: When performing calibration in Station F2 by using the calibration
tool.
Gantry2: When performing calibration in Station R2 by using the calibration
tool.
<Axis> combo box
Select the axis to be compensated. Compensation can be made only for the X
axis.