2. “The message, “Move To Center Position of [Fix 1] Camera. To Move, Click
[Next]” is displayed in the message window. Click the <Next> button to move
the head assembly to the center of the Fix 1 Camera.
3. The message “1. First, Select Move Camera and Adjust Light Level. 2. After
that, Select Fix-camera and Adjust Light Level. 3. To Calibrate, Click [Next]”
appears. Then click the <Light…> button first and adjust the brightness of the
light in the Light Control’dialog box so that the white circle at the center of the
Calibration Glass that is seen in the ‘SMVision’ window can be seen clerly.
4. Then select the ‘Fix1 Cam’ in the <Target Camera> combo box and click the
<Light…> button. Adjust the brightness of the light in the ‘Light Control’
dialog box so that the fiducial mark on the Calibration Glass that is seen in the
‘SMVision’ window can be seen clearly. Click the <Next> button.
5. The calibration is performed automatically. If it is completed, the calibration
result is indicated as shown in the following figure. Click the <Update> button
to apply the calibration value.
6. If the calibration procedure is completed properly, the result as shown in the
following figure is displayed and then the message, “Move (Fiducial/Teach)
Camera Offset is Finished. Remove Tool Plate!” appears. At this point, remove
the flat board calibration tool placed on the Fix 1 Camera. Otherwise, damages
may be caused by collision with the head.
The reference values for the calibration of the Fiducial Camera Offset is as follows.
Gnatry 1
Offset X : -210.5mm ~ -208.5mm
Offset Y : -1.0mm ~ 1.0mm
Gnatry 2
Offset X : 210.5mm ~ 208.5mm
Offset Y : -1.0mm ~ 1.0mm