SM411F_Service Manual.pdf - 第31页
Conveyor - SM411F 21 L510XW300 Standard Field Option L510XW350 Option 1 Factory Option Option type L610XW350 PCB Option 2 Conveyor Option Same coveyor system with SM421 (SM411F) Others - SM411F 22 (SM411F) Two pcs. of al…

Entry & Exit Shuttle Assy 조립기준
19
Assembly position of
outlet sensor
Stopper bracket must be fit to
the end within error of 2mm
Assembly position of
inlet sensor
PCB belt assembly
tension
Assembly standard: 91±10HZ
Shuttle driving belt
tension
Assembly standard: 125±10HZ
Width driving belt
tension
Assembly standard: 125±10HZ
Rock nut assembly
torque
Assembly standard: 95kgf.cm
(SM411)
Assembly standard of work zone assy.
Position of PCB sensor 38mm±1
PCB transfer belt 40±5 Hz
Measured at the center of belt
Synch belt 22±2.5 Hz
Measured at the center of belt
Width trimming belt 300±20 Hz Measured at the center of belt
Driving resistance of lead screw
pulley
0.6kgfcm Measured before motor connected
Tightening of lead screw rock nut 50Kgf.cm
• Work stopper speed
Ascending: Time from solenoid signal input to sensing of up sensor Æ 300±25msec
Descending : Time from solenoid signal input to sensing of down sensor Æ 250±25msec
• Shuttle stopper speed
Ascending : Time from solenoid signal input to completion of up stroke Æ 200±25msec
Descending : Time from solenoid signal input to completion of down stroke Æ 200±25msec
• Edge fixer Æ The pressure of regulator at consignment is set to 0.1Mpa(±20%) and can be
changed according to weight, material and thickness of PCB. When setting the edge pressure,
drive the solenoid so that air pressure is applied to the regulator.
20
(SM411)

Conveyor - SM411F
21
L510XW300Standard
Field OptionL510XW350Option 1
Factory Option
Option type
L610XW350
PCB
Option 2
Conveyor Option
Same coveyor system with SM421
(SM411F)
Others - SM411F
22
(SM411F)
Two pcs. of alarm lamp for conveniently telling
Operator can easily find out which side of the machine
has problem with shortage of components or minor
errors
Cover for Side Tray is standard

Others - SM411F
23
(SM411F)
-. For effectively blocking the dropping components
Chip Cover
Cable protecting cover
-. Tap is prepared for User Backup Block
Back up table & etc
Others - SM411F
24
(SM411F)
Automatically detecting Flux and injecting
Flux dipping device for POP process