Softwar e Module No Constant Name Classification Va l u e Unit Description 34 OPT_NZ_VIS_CHK Use 0 Const Check if there is a nozzle in the ANC pocket before placing the nozzle. 0: It does not check. 1: It checks. 64 Syst…

100%1 / 245
Software
Module
No
Constant Name Classification
Value
Unit Description
35
TMV_PIN_DELAY Use 200 msec
The dela
y
time until the hole fix sensor do
g
is detected since the BUT
moved up.
36
TMV_EDGE Use 3000 msec Timeout in operating the edge fix.
37
TMV_IN Use 10000
msec Timeout in transferring the PCB from a zone to next zone.
38
TMV_OUT Use 10000
msec Timeout in transferring the PCB to the next machine.
39
TMV_OUT_PUSH Use 2000 msec
The time durin
g
which the PCB is pushed continuousl
y
when it is out of
the detection range of the ‘Out Sensor’ while transfering the PCB.
85
TMV_EDGE_DELAY Use 300 msec
0: The sensor for the Edge Fix is used.
Others: It is recognized that the edge fix functioned properly after the
given delay without the sense of the edge fix sensor. (300msec)
27
LARGE_PCB_SIZE_X 0
Default : 0 ,
Input the corresponding value when setting the X size of the large PCB
to more than 460mm.
95
BUT_DOWN_DELAY Use 500 msec
Delay until operating the work zone conveyor after the BUT UP sensor
has been turned off.
96
Debug
CONV_OUT_DEC_TIME Use 200 msec
Time delay from the time the conveyor was stopped after the PCB had
been detected by the Out Zone Sensor until it starts to move.
Docking 63
System OPT_DC_SAFETY Use 4 Const
Safety related sensor for the docking cart can be checked for each
option.
0: Check all safety sensors
1: Do not check the left/right docking detection sensor.
2: Do not check the door open state.
4: Do not check the docking cart cable connection state.
Mir 32
System OPT_USE_MIR_SAFETY Use 0 Const
Currently, it is set so that it does not change according to the value.
0: Not used
1: Used only when performing the homing
2:
Software
Module
No
Constant Name Classification
Value
Unit Description
34
OPT_NZ_VIS_CHK Use 0 Const
Check if there is a nozzle in the ANC pocket before placing the nozzle.
0: It does not check.
1: It checks.
64
System
OPT_ANC_SHUTTER Use 0 Const
Use the function to minimize the Open/Close movement of the ANC
shutter when getting the nozzle.
0: Not user
1: use
25
SYS_DELAY_ANC Use 200 msec The delayed time after the sense of the ANC sensor.
26
NZ_GET_DN_MARGIN Use 1200 um
he further amount of the down movement of the head when it moves
down to pick the nozzle.
90
NZ_EXIST_CHK_METHOD Use 1 Const
Set the method to check the existence of the nozzle.
0: Use the nozzle check sensor if it is CP45 and use pneumatic pressure
if it is CP55 or SM320(SM321).
1: Use the binary pixel count function that uses the vision system.
91
Factory
NZ_VIS_USE_CHK_VALUE Reserved 30 %
When checking the existence of the nozzle by using the vision system,
set the criteria for the nozzle existence check to white pixel 30%.
36
METHOD_VIS_NZ_CHK Use 1
Option for the recognition method for the vision system when checking
the existence of the nozzle by using the vision system.
0: Individual recognition method
1: Simultaneous recognition method
50
IGNORE_NOZ_CHK_SENSOR Use 0 0 , 1
When the nozzle check sensor has a problem, if this value is set to 1,
the sensor does not check the nozzle.
53
VIS_NZ_CHK_DELAY_TIME Use 50 msec
Time delay constant necessary for simultaneous recognition when
checking the nozzle existence by using the vision system.
ANC
58
Debug
ANC_SPEED_OPTI Use 1 const
Set the LookAhead function.
0: Not set, 1: Set
Software
Module
No
Constant Name Classification
Value
Unit Description
59
VIS_NZ_CHK_DISPLAY Use 0 const
0: Not displa
y
the dialo
g
box for the nozzle check b
y
the vision, 1:
Display it
Jog Box 40
System OPT_Z_CHK_AT_BANG_MODE Use 0 Const
Use Z Safety Check when performing XY movement in the Bang Bang
Mode of the JogBox.
0: Not Check, 1: Check
43
OPT_USE_VAC_PLATE Use 0 Const
0 : The vacuum plate function is not used. , 1 : Use the vacuum plate
function.
44
OPT_VAC_PLATE_CHK_DELAY Use 0 msec
Waitin
g
time until the check b
y
the Vacuum plate sensor after the PCB is
locked.
45
OPT_VAC_PLATE_OFF_DELAY Use 100
msec
Waiting time until the next movement after turnin
g
off the vacuum of the
vacuum plate.
60
OPT_VAC_DUMP_SAVER_TIME_O
UT
Use 300 sec
When the vacuum of the head is not used in the Idle mode, cut off the
vacuum pump after a given period of time.
66
OPT_PICK_VAC_CHK Use 1 Const
0:Not use the routine to check if the part is picked up or not when
picking the part.
1: Use the routine to check if the part is picked up or not when picking
the part.
67
System
OPT_VAC_CHK_MNT_LEVEL Use 30 mmHg
Reference vacuum to determine whether to pick up the part by using the
difference between the vacuum pressure just before the placement and
that for the recognition.
63
SYS_HEAD_VAC_DELAY Use 8 msec
Delay from the Z pulse ending to the creation of the vacuum Sol Off
signal.
64
SYS_HEAD_VAC_TIME Use 5 msec
The period of time from the time the vacuum Sol is turned off until the
vacuum is released.
65
SYS_HEAD_VAC_GEN_TIME Use 30 msec
The period of time from the time the vacuum Sol is turned off until the
vacuum is created.
66
SYS_HEAD_VAC_REL_TIME Use 30 msec
The period of time from the time the vacuum Sol is turned off
until release of the vacuum is stabilized.
Vacuum
67
Factory
SYS_HEAD_VAC_TIME2 Reserved 0 msec The time for minimum change when releasing the vacuum.