The result value can be confirmed in the Camera dialog box in the System Setup menu. The reference values for the calibration of the Head-Fly Offset is as follows. (Mega FOV 15) Offset X : -0.45 ~ 0.45 (m m) Offset Y…

<Target Camera> combo box and in the ‘Light Control‘ dialog box, adjust the
brightness of the lighting so that the ‘Fiducial Mark’ on the CNT20 nozzle can
be clearly seen in the ‘SMVision‘ window. Then click the <Next> button.
7. The calibration is performed automatically. If it is completed, the calibration
result is displayed as shown in the following figure. Click the <Next> button.
8. Then the message “Next, Remove the Calibration Tool From Head 1. Click
[Next] for Moving Down Head. After Moving, Remove the Nozzle Manually”
appears. Click the <Next> button to remove the CNT20 nozzle from the
nozzle-holder of Head #1 manually.
9. Form Head #2 to Head #6, perform calibration in the same manner as it was
performed for Head #1.
10. If the calibration procedure is completed for all heads normally, the result is
displayed as shown in the following figure. Click the <Update> button to apply
the calibration value.

The result value can be confirmed in the Camera dialog box in the System
Setup menu.
The reference values for the calibration of the Head-Fly Offset is as follows.
(Mega FOV 15)
Offset X : -0.45 ~ 0.45 (mm)
Offset Y : -0.45 ~ 0.45 (mm)
Offset R : -1.0° ~ 1.0°
The reference values for the calibration of the Head-Fly Offset is as follows (Mega
FOV 16)
Offset X : -0.60 ~ 0.60 (mm)
Offset Y : -0.60 ~ 0.60 (mm)
Offset R : -1.0° ~ 1.0°
"Memo

The reference values for the calibration of the Head Reference Fiducial Offset is as
follows
Offset X : -0.50 ~ 0.50 (mm)
Offset Y : -0.50 ~ 0.50 (mm)