1.2.8.1. Procedure
The gantry mapping method is as follows.
1. Referring to the following figure, perform teaching of the position of fiducial
mark 6 located on the upper surface of the conveyor.
2. < Click the <Move> button to move the fiducial camera to the designated
position.
3. Adjust the position of the fiducial camera by using the teaching box so that the
center of the cross hair displayed in the SMVision window matches with the
center of the fiducial mark that was already set on the conveyor.
4. Click the <Get> button to reflect the current coordinate.
5. Identically teach fiducial marks #2~#6 in the order as shown in the above
figure.
6. When the teaching of 6 fiducial marks for Gantry1F has been completed, the
teaching of 6 fiducial marks for Gantry1R is carried out. The method is the
same as Gantry1F.
Warning
Operation error caused by unauthorized or untrained
personnel or insufficient checking before calibration could
severely damage the machine or the set up data, or it
could cause personal injury of the operator or the worker
near the machine.
Before carrying out calibration, check the item to be
calibrated and check if there is any worker near the
machine.
And calibration must be carried out by an authorized and
trained user only.
1.2.9. ANC Pos. Scan
Teach the 2 fiducial marks on the top surface of the ANC. Compensate the relative
coordinate system of the front and rear ANCs.
Refer to Administrators Guide“6.3 Fiducial Mark Setup“ for more information.