00193370-0202.pdf - 第58页

Handbuch für das Achsprüfgerät / Axis T ester Manual SIPLACE Axis T e ster 7 Commissioning the axis tester Ausgabe 08/2003 Edition 58 7.1.2 Conn ecting the axis tester to S-15 /F3 /G place ment machines and wafflep ack c…

100%1 / 84
SIPLACE Axis Tester Handbuch für das Achsprüfgerät / Axis Tester Manual
Ausgabe 08/2003 Edition 7 Commissioning the axis tester
57
7 Commissioning the axis tester
7.1 Connecting the axis tester
WARNING 7
Always press the emergency stop button before connecting the axis tester to or disconnecting it
from the axis controller. 7
Æ Open the doors to the control unit.
Fig. 7 - 1 Section of the control unit in the HS-50 placement machine
7.1.1 Connecting the axis tester to HS /S2x F4/F5 machines
Æ Connect the 37-pin plug on the ribbon cable to the axis controller.
Æ Connect the 37-pin socket on the ribbon cable to the axis tester.
The axis tester boots up. If all the self tests are successful, the start-up screen appears.
Æ Carry out your diagnostics and settings as described in the setting instructions.
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Servo
Keyboard
Mouse
Off
Off
Off Off
Off
Off
Off
Off
Off Off
Off
Off Off
Off
Off
Off
Off
Off Off
Off
Off
Axis controllers in the HS-50 control unit with 37-pin sockets
Handbuch für das Achsprüfgerät / Axis Tester Manual SIPLACE Axis Tester
7 Commissioning the axis tester Ausgabe 08/2003 Edition
58
7.1.2 Connecting the axis tester to S-15 /F3 /G placement machines and wafflepack
changers
Æ Connect the adapter to the 37-pin plug on the ribbon cable.
Æ Connect the 25-pin plug on the adapter to the socket on the axis controller.
Æ Connect the 37-pin socket on the ribbon cable to the axis tester.
The axis tester boots up. If all the self tests are successful, the start-up screen appears.
Æ Carry out your diagnostics and settings as described in the setting instructions.
7.2 Disconnecting the axis tester from the placement machine
Once you have completed your measurements on an axis controller, remember to save your
changes before you disconnect the ribbon cable. The procedure is as follows:
Æ Select the “Shutdown” option from the main menu.
Æ Select the “Shutdown computer: Yes” menu option.
When you click on “Yes”, all your settings are saved and the axis tester is shut down.
WARNING 7
Press the emergency stop button. 7
Æ You can now unplug the axis tester from the ribbon cable of the axis controller.
SIPLACE Axis Tester Handbuch für das Achsprüfgerät / Axis Tester Manual
Ausgabe 08/2003 Edition 8 Using the menus
59
8 Using the menus
8.1 Starting the axis tester and selecting the user level
When you connect the axis tester to the axis controller in the control unit or after a reset, the CPU
restarts the axis tester. This loads the program and runs a number of self tests. The progress of
these tests is indicated by the dotted line at the bottom of the display.
Fig. 8 - 1 Display after booting
Once all the tests have been completed successfully, the start-up page appears on the display.
Fig. 8 - 2 Start-up window, rebooting the axis tester
Self test progress indicator
Activate “Expert” mode:
To do this, press both keys simultaneously
during start-up. This displays a window to
confirm that “Expert mode” has been acti-
vated.
The current software version
Last saved configuration
Transmission speed for CAN bus or V24
port
Button for calling up the main menu
Press these three buttons simultaneously