D-serie LEVEL II.pdf - 第121页
Axis Dynamics Checking the Y-Axis Dynamics Gantry Axis Control S tude nt Guide Advanced Level 2 SIPLACE D Series EN 05/2007 Axis Dynamics 7-15 7.4.3 Checking the Y -Axis Dynamics 7.4.3.1 M easurement Setup 7.4.3.2 Y -Axi…

Axis Dynamics
Gantry Axis Control Checking the X-Axis Dynamics
Student Guide Advanced Level 2 SIPLACE D Series
Axis Dynamics EN 05/2007
7-14
7.4.2.3 X-Axis Travel Time Table (D1/D2)
7.4.2.4 X-Axis Travel Time Table (D3)
In software version 603 the gantry travel times for the C&P head are about 5 ms faster than before:
7.4.2.5 X-Axis Travel Time Table (D4)
D1 machine: C&P6 or C&P12 + P&P D2 machine: C&P6 or C&P12
Range / digit Target time / ms Tolerance /ms Target time / ms Tolerance /ms
500 30 +/-5 33 +/-5
1000 33 +/-5 35 +/-5
2000 39 +/-5 37 +/-5
5000 48 +/-5 43 +/-5
15000 60 +/-5 56 +/-5
20000 66 +/-10 64 +/-10
50000 95 +/-10 88 +/-10
100000 126 +/-10 117 +/-10
200000 174 +/-15 159 +/-15
300000 214 +/-15 199 +/-15
Range / digit X gantry axis (C&P6, C&P12) X gantry axis with Twin head
Target time / ms Tolerance /ms Target time / ms Tolerance /ms
50021+/-525+/-5
100024+/-528+/-5
200030+/-534+/-5
500042+/-541+/-5
15000 53 +/-5 54 +/-5
20000 59 +/-5 59 +/-5
50000 82 +/-10 87 +/-10
100000 121 +/-10 125 +/-10
200000 169 +/-10 170 +/-10
300000 208 +/-15 209 +/-15
Travel times with 603 for X gantry axis, with the various different head configurations
X-axis gantry axis with DLM2 (C&P12)
Range / digit Target time / ms Tolerance /ms
500 32 +/-5
1000 34 +/-5
2000 38 +/-5
5000 45 +/-5
15000 56 +/-5
20000 63 +/-5

Axis Dynamics
Checking the Y-Axis Dynamics Gantry Axis Control
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Axis Dynamics
7-15
7.4.3 Checking the Y-Axis Dynamics
7.4.3.1 Measurement Setup
7.4.3.2 Y-Axis Travel Time Table (D1/D2)
50000 87 +/-10
100000 114 +/-10
200000 162 +/-10
300000 205 +/-15
X-axis gantry axis with DLM2 (C&P12)
Range / digit Target time / ms Tolerance /ms
NOTE:
The measurement procedure is prepared and performed identically to that for the X-axis
D2: C&P6 or C&P12 D1: C&P6 or C&P12 and P&P
Range / digit Target time /
ms
Tolerance /ms Range / digit Target time / ms Tolerance /ms
500 45 +/-5 500 45 +/-5
1000 50 +/-5 1000 50 +/-5
2000 59 +/-5 2000 62 +/-5
5000 66 +/-5 5000 75 +/-5
15000 79 +/-10 15000 91 +/-10
20000 90 +/-10 20000 105 +/-10
50000 118 +/-10 50000 133 +/-10
100000 150 +/-10 100000 172 +/-10
200000 196 +/-15 200000 228 +/-15
600000 378 +/-15 600000 425 +/-15

Axis Dynamics
Gantry Axis Control Checking the Y-Axis Dynamics
Student Guide Advanced Level 2 SIPLACE D Series
Axis Dynamics EN 05/2007
7-16
7.4.3.3 Y-Axis Travel Time Table (D3)
In software version 603 the gantry travel times for the C&P head are about 5 ms faster than before:
7.4.3.4 Y-Axis Travel Time Table (D4)
Range / digit Y gantry axis (C&P6, C&P12) Y gantry axis with Twin head
Target time / ms Tolerance /ms Target time / ms Tolerance /ms
50033+/-535+/-5
100034+/-540+/-5
200037+/-546+/-5
500044+/-553+/-5
15000 61 +/-5 68 +/-5
20000 68 +/-5 76 +/-5
50000 96 +/-10 108 +/-10
100000 139 +/-10 147 +/-10
200000 190 +/-10 199 +/-10
600000 347 +/-15 357 +/-15
Travel times with 603 for Y gantry axes, with the various different head configurations
D4: Y gantry axis with DLM3 (DLM2) (C&P12)
Range / digit Target time / ms Tolerance /ms
500 41 +/-5
1000 43 +/-5
2000 45 +/-5
5000 55 +/-5
15000 70 +/-5
20000 75 +/-5
50000 108 +/-10
100000 143 +/-10
200000 188 +/-10
600000 370 +/-15