9.1 Overview
This chapter describes the preparation of components with the component changeover tables, the
corresponding docking unit and the pneumatic cutter.
Up to four flexible changeover tables can be docked onto the D4/D3 (D1/D2: two) machine. The
changeover tables are automatically connected to/disconnected from the docking unit at the press of a
button. Plug-in electrical and pneumatic connections link the machine to the changeover table.
9-1: Positions of changeover tables and buttons for docking and undocking the tables (D4)
The table unit consists of the changeover table and the mechanics for raising and lowering the
changeover table.