SITEST Calibration Steps and Individual Calibrati on Functions New Functions in SITEST S tuden t Guide Advanced Level 2 SIPLACE D Series SITEST EN 05/2007 12-20 Pick up CT with seg. 1 and measure 8 times in 90° steps. Ca…

100%1 / 228
SITEST
New Functions in SITEST Calibration Steps and Individual Calibration Functions
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 SITEST
12-19
Pick up calibration tool and
measure in comp. camera
center in 90° steps.
Repeat measuring
procedure.
Calibrate camera fiducial.
Repeat measuring
procedure.
Save in camera.xml.
Calibrating comp. camera 2
(head 2 P&P module) option
YES
With TWIN
YES Automatically in 'all heads/
cameras' with Vision image
Measure head height on
conveyor and camera.
Move PCB camera to calib.
tool and calibrate.
Calibration nozzle 517
Pick up calib. tool and
measure near the 4
corners.
As single step in: 'P&P
module' 'comp. camera 2
calib.'
Pick up calibration tool and
measure in comp. camera
center in 90° steps.
Repeat measuring
procedure.
Calibrate camera fiducial.
Repeat measuring
procedure.
Save in camera.xml.
Calibrate head (head 1 RV ..
head ) (with comp. camera)
YES Automatically in 'all heads/
cameras' with Vision image
Move PCB camera to calib.
tool and calibrate.
As single step in: 'C&P head/
RV head' 'comp. camera
calib'
Check the results there.
Calibrate camera. 956 nozzle
Pick up calib. tool and
calibrate comp. camera.
Return CT.
Save in camera.xml.
Calibrate head.
Segment offset I
Measure CT with PCB
camera.
Calibration step/
individual calibration
function
For D4 For D3 For D2 For D1 Comments
SITEST
Calibration Steps and Individual Calibration Functions New Functions in SITEST
Student Guide Advanced Level 2 SIPLACE D Series
SITEST EN 05/2007
12-20
Pick up CT with seg. 1 and
measure 8 times in 90°
steps.
Calibrate segment offset I
(top).
Rotary axis of segment to
comp. camera center
Repeat this with all
segments.
Save in Pip_off.ma.
Segment offset II
Measure CT pos. with PCB
cam. / pick up with seg.1 in
0° pos./ opt. centering &
return.
Segment pickup angle in the
4 90° steps
Repeat previous step with
seg.1 in 90; 180, 270° pos.
Repeat the two previous
steps with all other
segments.
Save in Pip_off.ma.
For saving, see -->
Calibrating head (head 2
P&P module )
YES
With TWIN
YES Automatically in 'all heads/
cameras'
Calibrate camera position
for comp. camera 1 and 2.
As single step in: 'P&P
module' 'head calib.' 'head
calib.' / segment calib.
The positions of the
stationary cameras are
measured in 90° steps.
517 nozzle
Save in camera.xml.
Calibrating nozzle changer
head 1
YES In 'all heads/ cameras', in part
with Vision image
During automatic calib. the
1st fiducial is not shown to
operator for confirmation;
the pickup/place sequence
runs through to end .*
With single step, the 1st
fiducial is shown to the
operator for confirmation.
The pickup/place sequence
is processed as if segment 1
is occupied.
Measure X/Y position of
magazine and reject
position with PCB camera.
As single step in: 'C&P head/
RV head' 'Nozzle ch.
magazine function.' 'noz. ch.
calib.' You can select/
deselect the reject pos. /
pickup height.
The pickup height is
calculated by picking up/
placing a nozzle in garage 1
with segment 1.
"Pickup height" measurement is performed fastest with an empty segment 1 and
a full garage 1 in all magazines.
Save in PPW_ver.ma.
Calibration step/
individual calibration
function
For D4 For D3 For D2 For D1 Comments
SITEST
New Functions in SITEST Calibration Steps and Individual Calibration Functions
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 SITEST
12-21
Calibrating nozzle changer
head 2
YES
With TWIN
YES In 'all heads/ cameras', in part
with Vision image
During automatic calib. the
1st fiducial is not shown to
operator for confirmation;
the pickup/place sequence
runs through to end .*
With single step, the 1st
fiducial is shown to the
operator for confirmation
Measure X/Y position of
magazines and whole
changer with PCB camera.
As single step in: 'C&P head/
RV head' 'Nozzle ch.
magazine function.' 'noz. ch.
calib.' You can select/
deselect the reject pos. /
pickup height.
The pickup height is
calculated by inserting a
5xx nozzle into an empty
garage.
TWIN module 1 must carry one nozzle and there must be one garage empty in all
the magazines. This is required for measurement in automatic mode to be
performed.
Save in PPW_ver.ma.
Calibrating coplanarity
(head 2 P&P module) (1 D
coplanarity)
YES
With TWIN
& ILD
YES
With
ILD2200
Semi-automatically in 'all
heads/ cameras' without
Vision image
After all calibrations with the
Vision CT have been
completed, the procedure
stops with 'prepare PA'.
517 nozzle
The Vision CT must be
replaced with the coplanarity
CT.
Copl. CT is picked up.
Measure on the top edge of
the conveyor side.
As single step in: 'P&P
module' 'coplanarity'
'calibrate coplan.'
The focus height of the laser
is measured.
The X/Y outer edges of the
coplanarity CT are
measured in 90° steps, to
determine the laser beam
position.
Save in coplan.ma.
Semiautomatic calibration menus or menus which are activated in single step mode.
Calibrating the conveyor
sides
YES To be manually calibrated
The position of the flexible
conveyor side when moving
apart is measured in 30 (12
dual conveyor) steps.
As single step in 'conveyor'
'calibrate conveyor'
Calibration step/
individual calibration
function