D-serie LEVEL II.pdf - 第85页
Energy and Compressed Air Supply Bulk Case System Room for Your Sketches and Notes S tude nt Guide Advanced Level 2 SIPLACE D Series EN 05/2007 Energy and Compressed Air Supply 5-19 5.4 Room for Y our Sketches and Notes

Energy and Compressed Air Supply
Pneumatic System Compressed Air Supply to Tape Cutter
Student Guide Advanced Level 2 SIPLACE D Series
Energy and Compressed Air Supply EN 05/2007
5-18
5.3.4 Compressed Air Supply to Tape Cutter
5.3.5 Bulk Case System
Another manually adjustable regulator is used to reduce the 5.0 bar to 2.5 +0.5 bar. This air supply is
used for bulkcase feeders, for the C&P nozzle changers of D1/D2 and possibly for some options.
5-15: Compressed air supply to tape cutter
Legend
1. Cylinder with dynamic end position (prevents
loud crash noise) for moving along the cutting
edge (40 mm)
2. Adjustment valve for the cylinder concerned
3. 5/2 way valve
4. Air supply - 5.1 +/- 0.1 bar switched via SSK -
protective contactor combination - (if SSK
enabled)

Energy and Compressed Air Supply
Bulk Case System Room for Your Sketches and Notes
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Energy and Compressed Air Supply
5-19
5.4 Room for Your Sketches and Notes

Energy and Compressed Air Supply
Room for Your Sketches and Notes Bulk Case System
Student Guide Advanced Level 2 SIPLACE D Series
Energy and Compressed Air Supply EN 05/2007
5-20