D-serie LEVEL II.pdf - 第76页

Energy and Compressed Air Supply Power Supply Unit Assemblies in Sector 4 S tuden t Guide Advanced Level 2 SIPLACE D Series Energy and Compressed A ir Supply EN 05/2007 5-10 5.2.8 Assemblies in Sector 4 5-6: (diagram rot…

100%1 / 228
Energy and Compressed Air Supply
Assemblies in Sector 2 Power Supply Unit
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Energy and Compressed Air Supply
5-9
5.2.6 Assemblies in Sector 2
5-5: Assembly in sector 2 (D4 shown as example, diagram rotated by 90° to left; some of the connectors are not present in D1/D2)
Naming convention for cables and connections in sector 2
Terminal strip (voltage supply) X200
Connections (plug-in connectors) bf
CAN I/O module qc (assembly A1)
CAN interface re (assembly A2)
CAN Bus board for changeover table rf (assembly A3)
In D1/D2 machines, the following subdistributor designations apply for the subassemblies:
A3: qf
A2: qe
5.2.7 Assemblies in Sector 3
Naming convention for cables and
connections in sector 3
Terminal strip (voltage supply) X300
Connections (plug-in connectors) cf
CAN Bus terminator for changeover table rd
Energy and Compressed Air Supply
Power Supply Unit Assemblies in Sector 4
Student Guide Advanced Level 2 SIPLACE D Series
Energy and Compressed Air Supply EN 05/2007
5-10
5.2.8 Assemblies in Sector 4
5-6: (diagram rotated by 90°)
Naming convention for cables and connections in sector 4
Terminal strip (voltage supply) X400
Connections (plug-in connectors) df
CAN I/O module qb
CAN interface qe
CAN Bus terminator for changeover table qf
5.2.9 Voltages in the Power Supply Unit After Switching On
When the main switch is activated, the following voltages are generated, sent to the modules and
released or held ready for release:
Voltages Module State
250 VDC X/Y servo module not enabled
150 VDC Star servo not enabled
34 VDC PCB handling system Released up to SZ2
24 VDC tape cutter not enabled
34 VDC SZ1 main power inrush current enabled
52 VDC DC/DC converter main power supply enabled
52 VDC Camera illumination enabled
40 VDC Power fail A3 enabled
42 V DC Z/DP axes enabled
40 VDC Feeder table plate enabled
28 VDC Monitor enabled
24 VDC fan enabled
230 or 115 or 240 VAC service socket independent of the main switch
NOTE:
The service socket can only be used if the placement system is connected to the main power
supply with a 5-conductor cable (L1, L2, L3, N, PE).
Energy and Compressed Air Supply
Power Supply for Axis Unit Power Supply Unit
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Energy and Compressed Air Supply
5-11
5.2.10 Power Supply for Axis Unit
5-7: Power supply for axis unit (new version)
After activating the main switch, the axis unit is
supplied with power from the main power supply,
via X8 for axis unit 1 and X9 for axis unit 2. It is
supplied with 48 VDC and the following voltages
are generated:
+/-15 V and +/-15/5 V
This DC/DC converter generates the 5V and +/-
15V needed for the servo board and the axis
controller
5-8: Power supply for axis unit (old version)