D-serie LEVEL II.pdf - 第67页

Energy and Compressed Air Supply Overview S tude nt Guide Advanced Level 2 SIPLACE D Series EN 05/2007 Energy and Compressed Air Supply 5-1 5 Energy and Compressed Air Supply 5.1 Overview 5-1: Main components in SIPLACE …

100%1 / 228
Communication and Control
Room for Your Sketches and Notes Component Camera (Standard Type 36, Option Type 33)
Student Guide Advanced Level 2 SIPLACE D Series
Communication and Control EN 05/2007
4-26
Energy and Compressed Air Supply
Overview
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Energy and Compressed Air Supply
5-1
5 Energy and Compressed Air Supply
5.1 Overview
5-1: Main components in SIPLACE D4
The diagram shows where the energy supplying and distributing components for system operation are
installed:
Legend
1 Sector distributor for sector 1 5 Transport direction
2 Sector distributor for sector 2 (only by D4 on the
back of the machine)
6 Pneumatic Unit
7 Power Supply Unit
3 Sector distributor for sector 3 8 Controls (keyboard and monitor)
4 Sector distributor for sector 4 (this area is sector
2 in D1/D2)
9 Error display (right-hand machine side)
Energy and Compressed Air Supply
Power Supply Unit Overview of Power Supply
Student Guide Advanced Level 2 SIPLACE D Series
Energy and Compressed Air Supply EN 05/2007
5-2
5.2 Power Supply Unit
5.2.1 Overview of Power Supply
The main power supply unit is mounted on a compact slide-in module, and located on the left side of the
middle section. When viewed from the outside only the red main power switch is visible.
A lockable door prevents access to the power supply.
With the open cover, the state of the following protective devices can be quite easily monitored.
Motor protection switch
main contactor
Safety relay
Power circuit breaker
The following work must be performed to adjust the power supply to the country-specific requirements
(see also the conversion instructions for 3x 208 V to 3x 400 V and vice versa):
X Rewiring line supply cable/transformer
X Motor protecting switch
X Inrush current limiter connections
5-2: Main power supply - side view
Legend
NOTE:
Unless otherwise specified, the wiring examples shown in this section apply for SIPLACE D4
machines. Refer to the relevant circuit diagrams for all other machine types.
1 Transformer 1 7 Power supply A1 (24 V/40 A)
2 Secondary terminal strip with fuses (output
voltage T1)
8 Line filter Z1 (input voltage)
8 Line filter Z1 (input voltage)