10 Tg0742-PM-SO 0301-001 3. Pre-Installation Check • Ambient temperature must be 20 ± 10°C and humidity 30% to 80%. Any dew condensation must be avoided. • When the machine is transferred to another place and the ambient…

100%1 / 85
9 Tg0742-PM-SO
0301-001
2. Warning Label Positions
2. Warning Label Positions
Indications for Laser Beam
Fig. X2
Fig. X3
V. Bend Detection Unit
WARNING
Main Machine Rear View
Main Machine Front View
10 Tg0742-PM-SO
0301-001
3. Pre-Installation Check
Ambient temperature must be 20 ± 10°C and humidity 30% to 80%. Any dew condensation
must be avoided.
When the machine is transferred to another place and the ambient temperature rises more
than the surface of the machine, dew may condense under the condition described below.
Note that dew condensation may cause the machine to break down.
Condition of Dew Condensation
Dew may condense when the differences (based on "Humidity (%)") between the ambient
and surface temperatures of the machine reach the values or more in the table below.
3. Pre-Installation Check
80
70
60
50
40
30
Differences between Ambient Temperature of
Destination and Surface Temperature of Machine
3°C or more
6°C or more
8°C or more
10°C or more
14°C or more
18°C or more
Humidity (%) of Destination
11 Tg0742-PM-SO
1. Scope
This function detects accurately the lead bend amount (bend to
upper and lower direction) for QFP and lifted ball for BGA.
2. Specifications
0301-001
1. Scope