SOM-1655-002.pdf - 第50页

49 Tg0742-PM-SO [Scan For Fitting] Button When this button is pressed, the following window appears. 0301-001 12.1 Adjustment for Sensor Head Installation Fig. 28 "Scan For Fitting" Window Operation Procedure (…

100%1 / 85
48 Tg0742-PM-SO0301-001
12.1 Adjustment for Sensor Head Installation
[All Beam Zero] Button (The left of the window)
Each of the X-, Y-, and L-axis are zeroed.
For actual proceed, press the [ON] button and then start by
pressing the [ENABLE] button on the operation panel.
[Jig Comp. Pickup & Fxd Camera Move] Button
After picking up the correction jig by the specified nozzle on the
specified head, the nozzle is moved into position for the camera
A1 and recognized by the camera.
Before this operation, the vacuum nozzle has to be
attached onto the head.
[Component Collection] Button
The correction jig picked up by the specified nozzle on the speci-
fied head is returned to the jig stocker.
If the head and the nozzle for picking up the jig are not cor-
rectly specified, the jig cannot be returned.
When the sensor head position is moved, the jig stocker posi-
tion is also changed and the jig cannot be correctly returned. In
this case, remove the jig manually, and return the jig to the
stocker after the jig returning operation of the machine.
[Rough Positioning] Button
The jig is moved to the center of the detection area for rough
positioning of the sensor head.
Before this operation, the vacuum nozzle has to be
attached to the head.
49 Tg0742-PM-SO
[Scan For Fitting] Button
When this button is pressed, the following window appears.
0301-001
12.1 Adjustment for Sensor Head Installation
Fig. 28 "Scan For Fitting" Window
Operation Procedure
(1) Select the head and nozzle to be detected. When the indi-
vidual head and nozzle are selected, this selected vacuum
nozzle operates as the nozzle of arrangement No. 1 (down-
ward).
When [All Heads] and [All Nozzles] are selected, before this
operation, reset the nozzle which has been already attached
to the head in the nozzle stocker, and put the nozzle for
picking up the correction jig in the No. 10 stocker in the
nozzle stocker B1.
(2) For "Scan Times", the number of detection operations is set.
Normally, set it to 6.
(3) For "Direction", the direction of the jig used for the detection
is set.
It is required to set "All Heads" and "All Nozzles" and detect
them at all specified angles.
50 Tg0742-PM-SO
[Scan Reference Nozzle] Button
After "Scan For Fitting" operation, the reference nozzle is de-
cided. Then the reference nozzle is used to detect. As the sensor
head installation condition is found on the basis of the detections,
the sensor head position is so adjusted that it is close to the
target value.
When this button is pressed, the following window appears.
0301-001
12.1 Adjustment for Sensor Head Installation
Fig. 29 "Scan Reference Nozzle" Window