SOM-1655-002.pdf - 第21页

20 Tg0742-PM-SO 0301-001 6. Operation Data 6. Operation Data • • • • • Sheet Layout When the [PCB Data] tab is pressed on the "Operation Data" tab sheet, the following tab sheet appears. Fig. 6 "PCB Data&q…

100%1 / 85
19 Tg0742-PM-SO
5. V. Bend Detection Setting Procedure
0301-001
5. V. Bend Detection Setting Procedure
Operation Data Setting
Component Library (Control) Setting
Component Recog. Test
Auto Operation
Set the operation data.
Refer to "6. Operation Data" for details.
Set the component library (control).
Refer to "7. Component Library" for details.
The V. bend detection setting is confirmed in
the component recognition test.
Refer to "10. Component Recog. Test" for
details.
20 Tg0742-PM-SO0301-001
6. Operation Data
6. Operation Data
Sheet Layout
When the [PCB Data] tab is pressed on the "Operation Data" tab
sheet, the following tab sheet appears.
Fig. 6 "PCB Data" Tab Sheet
Sheet Composition
This tab sheet is used for indication or entry of each data.
Refer to "4.1 Basic Operations" in "Section 2"
(the instruction manual (Vol. 3) of the main machine) for the
detailed information on how to enter parameters.
*1 V Bend Detection
V. bend detection function is set.
Enable : V. bend detection function is used.
Disable : V. bend detection function is not used.
*1
21 Tg0742-PM-SO0301-001
7. Component Library
7. Component Library
Sheet Layout
When the [Control Data] tab is pressed, the "Control Data" tab
sheet will appear.
Fig. 7 Example of "Control Data" Tab Sheet (IC (Simple))
Sheet Composition
This tab sheet is used for indication or entry of each data.
Refer to "4.1 Basic Operations" in "Section 2" (the instruc-
tion manual (Vol. 3) of the main machine) for the detaild
information on how to enter parameters.
*1 V. bend DETN
Mode
V. bend detection function is set.
Enable : V. bend detection function is used.
Disable : V. bend detection function is not used.
Retry
The retry function is set.
The retry function is to detect a V. bend again, with a different
setting; this when the height for scanning is deviated or the
detection result is NG (no good), due to incorrect setting in V.
bend detection operation.
Lead coplanarity tol [mm]
The tolerance of the height deviation for the Iead is set. If the
V. bend is larger than the set value, it is judged as NG (no
good).
*1