192277 - Micron Technical Reference Volume 3.pdf - 第204页
FOREIGN MACHINE INTERFAC E FMI POD 33.2 Technical Reference Manual Chapter Issue 5, Aug 14 FMI POD The FMI Pod is only used where both the upline and downline are using SMEMA, Fuji or Panasonic interfaces. For all other …

FOREIGN MACHINE INTERFACE
INTRODUCTION
Chapter Issue 5, Aug 14 Technical Reference Manual 33.1
CHAPTER 33 FOREIGN MACHINE INTERFACE
INTRODUCTION The Foreign Machine Interface (FMI) is an electrical means of communication
between the DEK machine and an adjacent machine/conveyor, using electrical
signals. The signals are transferred using opto-couplers and/or solid state
relays which keep the machines electrically isolated.
The DEK machine can interface with many different types of adjacent machine.
The machines utilize a set of timing and control signals (protocols) for commu-
nication with adjacent machines. There are two different types of interface
available for the DEK machine:
• An FMI Pod for SMEMA, Fuji or Panasonic protocols
• A Multi-Interface Unit (MIU) for all other protocols
The FMI Pod and the MIU are supplied with the following cables:
• An FMI loom which connects the FMI port on the machine controller, to the
MIU or FMI Pod
• Two interface cables, one cable for each adjacent machine
The adjacent machine/conveyor can be in the following configurations:
Figure 33-1 Machine Arrangements for Board Transfers
Left to Right Board Transfers
Right to Left Board Transfers
Upline
Downline
UplineDownline
Left to Left Board Transfers Right to Right Board Transfers
Upline
Downline
Upline
Downline
DEK
Machine
DEK
Machine
DEK
Machine
DEK
Machine
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor
Adjacent
Machine/
Conveyor

FOREIGN MACHINE INTERFACE
FMI POD
33.2 Technical Reference Manual Chapter Issue 5, Aug 14
FMI POD The FMI Pod is only used where both the upline and downline are using
SMEMA, Fuji or Panasonic interfaces. For all other interfaces refer to the MIU
interface later in this chapter.
The FMI Pod is a communications interface that allows DEK Printing Machines
to communicate with upline and downline board handlers.
NOTE
The FMI Pod is located at the front of Type 4 machines and accessed by
removing the front panel.
External Service Panel
M28SK02
POWER ON
PART No. 160740
M/C AVAILABLE
BOARD AVAILABLE
BOARD FAIL
DOWNLINE
BOARD AVAILABLE
BOARD FAIL
M/C AVAILABLE
UPLINE
M28PL01
FMI POD

FOREIGN MACHINE INTERFACE
FMI POD
Chapter Issue 5, Aug 14 Technical Reference Manual 33.3
Figure 33-2 FMI Schematic
NC
NC
NC
NC
NC
NC
Upline Board
Fail I/P
Send Down
line O/P
0V
NC
NC
NC
+12V
NC
Down
line Ready
I/P
NC
NC
NC
Down
line Board
Fail O/P
NC
Send Upline O/P
Upline Ready
I/P
NC
+24V SW
NC
M36 Machine
Contro
l Enclosure
FMI Pod
Ready
to Receive
Downline O/P
NC
Upline Board
Fail O/P
NC
Send Down
line I/P
NC
0V I/P
NC
+12V
NC
Down
line Board
Fail I/P
NC
Send Upline I/P
NC
Ready
to Receive
Upline O/P
Ready
to Receive
Upline O/P
NC
Downline Board
Fail
+24V SW
NC
NC
Downline Board
Fail 0V Return
M36SK04
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
01
01
02
02
03
03
04
04
05
05
06
06
07
07
08
08
09
09
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
M28PL01
M28SK02
NC
NC
NC
NC
NC
NC
DEK M/C Ready
Down
line Board
Available
Down
line M/C Ready
NC
Upline Board
Fail
NC
NC
NC
NC
NC
DEK M/C Ready
0V Return
NC
Downline M/C Ready
0V Return
Upline Board
Fail 0V Return
NC
NC
NC
Upline Board
Availab
le
Downline Board
Available 0V Return
NC
NC
Upline Board
Available 0V Return