192277 - Micron Technical Reference Volume 3.pdf - 第48页

CAMERA SYSTEM MODULE ADJUSTMENTS AND SETTINGS 23.6 Technical Reference Manual Chapter Issue 9, Feb 18 ADJUSTMENTS AND SETTINGS X Camera Home Positioning The position of the sensor and vane is fixed, therefore no adjustme…

100%1 / 276
CAMERA SYSTEM MODULE
ELECTRICAL SCHEMATIC
Chapter Issue 9, Feb 18 Technical Reference Manual 23.5
Figure 23-4 Linear Drive Schematic
PC
P
C
I
B
u
s
Motherboard
USB
M36 Machine
Control Enclosure
NextMove
Interface
NextMove ES
(I/O Node 1)
M36PL35
CAN Bus
Main Machine
I/O Node 2
N2SK2
CAN In
16SK14
16SOL14
Board
Stop
DIG OUT 10
N2PL4
0V
Board Stop Extended
10SE20
Board At Stop
10SE07
10SK24
M36PL11
0V
+12V
DIG IN 8
+12V
0V
DIG IN 9
NOTE
The breaks in the CAN Bus chain reflect1.
that additional I/O Nodes may be fitted,
refer to Machine Control chapter for the
complete CAN Bus chain.
2. HawkEye encoder edge connector is
fitted to Axis 0 (M36PL06) when the
HawkEye option is used.
3. Camera encoders are reverse wired.
Motor
3~
Hall W+
Hall V+
Hall U+
X Linear Motor
10SK29
Camera X Encoder
10EN1
Camera Y Home
10SE02
10SE02
8PL27
M36PL19
M36PL15
Camera X Home
10SE01
10SE01
EuroFlex
Axis 0
M36PL07
M36PL06
M36PL05
A OUT 0
10SK37
10SK31
Motor
3~
Hall W+
Hall V+
Hall U+
Y Linear Motor
10SK30
Camera Y Encoder
10EN2
M36PL03
M36PL02
10SK38
10SK32
M36PL01
EuroFlex
Axis 1
A OUT 1
Digital Camera
3PL55
Power
GND
TP B-
TP B+
TP A-
TP A+
10PL17
M36PL16
Trigger
0V
+24V US
0V
10SK13
PCI Interface
Card
10SK33
10SK34
See Note 2
CAMERA SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
23.6 Technical Reference Manual Chapter Issue 9, Feb 18
ADJUSTMENTS AND SETTINGS
X Camera Home
Positioning
The position of the sensor and vane is fixed, therefore no adjustment is
possible.
Y Camera Home
Positioning
The position of the sensor and vane is fixed, therefore no adjustment is
possible.
X Axis Parallelism
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
STRONG MAGNET FIELD. A STRONG MAGNETIC FIELD EXISTS IN THE
VICINITY OF THIS LABEL. THIS MAY PRESENT A HAZARD TO PERSONNEL OR
EQUIPMENT.
))
PROHIBITION
ELECTROMAGNETIC FIELD. AN ELECTROMAGNETIC FIELD EXISTS WITHIN
THE MACHINE FROM THE LINEAR MOTORS. THESE MAY PRESENT A HAZARD
TO PEOPLE FITTED WITH AN IMPLANTED CARDIAC DEVICE. THE MOTOR
MANUFACTURER RECOMMENDS A SAFE DISTANCE OF AT LEAST 15MM.
PROHIBITION
ELECTROMAGNETIC FIELD. AN ELECTROMAGNETIC FIELD EXISTS WITHIN
THE MACHINE FROM THE LINEAR MOTORS. THESE MAY PRESENT A HAZARD
TO PEOPLE FITTED WITH AN IMPLANTED CARDIAC DEVICE. THE MOTOR
MANUFACTURER RECOMMENDS A SAFE DISTANCE OF AT LEAST 15MM.
PROHIBITION
STRONG MAGNETIC FIELD. A STRONG MAGNETIC FIELD EXISTS IN THE
VICINITY OF THE LINEAR MOTORS THAT REPRESENT A SERIOUS HAZARD TO
PEOPLE FITTED WITH METALLIC IMPLANTS.
PROHIBITION
STRONG MAGNETIC FIELD. A STRONG MAGNETIC FIELD EXISTS IN THE
VICINITY OF THE LINEAR MOTORS THAT MAY ACT UPON FERROUS OBJECTS
WHOSE MOVEMENTS COULD LEAD TO PERSONAL INJURY AND/OR DAMAGE
TO THE MACHINE.
NOTE
The X axis parallelism is factory set and shouldn’t normally need to be adjusted.
1. Select Open Cover Commands.
2. Select Carriage To Rear.
3. Select Unload Screen.
4. Open the front printhead cover.
5. Remove the stencil from the machine.
6. Close the front printhead cover.
7. Press the System button.
8. Select Back.
CAMERA SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
Chapter Issue 9, Feb 18 Technical Reference Manual 23.7
9. Select Maintenance.
10. Select Diagnostics.
11. Use Next or Previous to highlight Rail System.
12. Select Select Module.
13. Ensure that Home Rail Width is highlighted.
14. Select Run Diagnost.
15. Select Exit.
16. Use Next or Previous to highlight Rising Table.
17. Select Select Module.
18. Use Next or Previous to highlight Raise Table to Vision Height.
19. Select Run Diagnost.
20. Select Exit.
21. Use Next or Previous to highlight Rail System.
22. Select Select Module. The board clamps are released.
23. Open the front printhead cover.
24. Remove any tooling from the manual tooling plate.
25. Remove the board clamp from the front transport rail, Board Clamp
Replacement - Replacement Procedures section of the Transport Rails
Module chapter refers.
26. There are two versions of the rail setting jig (Part No. 191156) and they are
labelled:
Standard Rails (round belts)
Heavy Board Rails (flat belts)
27. Confirm which type of rails are fitted to the machine and select the appropri-
ate rail setting jig.
28. Place the jig on the manual tooling plate ensuring that the location pins on
the underside of the jig are located in the holes on the manual tooling plate.
Check there is no gap using a 0.05mm feeler gauge.