00191369-02.pdf - 第166页

5 Single Functions User Manual HS -50 5.2 Single functions, Gantry Soft ware Version S R.501.xx 12 /99 Issue US 166 t I I t 5.2.5.1 Functions The "Nozz le co nfigurati on revo lver h ead" scr een prov ides fun …

100%1 / 414
User Manual HS-50 5 Single Functions
Software Version SR.501.xx 12/99 Issue US 5.2 Single functions, Gantry
165
t IIt
5.2.5 "Nozzle configuration revolver head" screen
5
Å In the current screen for the single functions for Gantry x, click the symbol .
The user interface is switched to the "Nozzle configuration revolver head" screen (see Fig. 5.2 - 6
).
5
Fig. 5.2 - 5 "Nozzle configuration revolver head" screen
5
Key to Fig. 5.2 - 5
(1) The entry for the segment currently located in the changeover position is highlighted in light
blue.
(2) The arrow points to the number of the segment which is in the changeover position.
5
1 2
5 Single Functions User Manual HS-50
5.2 Single functions, Gantry Software Version SR.501.xx 12/99 Issue US
166
t IIt
5.2.5.1 Functions
The "Nozzle configuration revolver head" screen provides functions which allow you to change the
nozzle configuration and to then confirm that this change has been made. The required function
is carried out by clicking on the appropriate button. 5
NOTE
The functions "Return", "Pick up", "Remove" and "Replace" can only be carried out if a nozzle
changer is installed and configured in the machine options.
Settings: 5
5
One nozzle
If this radio button is activated, the functions "Return", "Pick up", "Remove", and "Replace" can
only be carried out for one selected nozzle. When you call one of these functions a dialog box ap-
pears. You can enter the number of the segment with the required nozzle.
By default the box already contains the number of the segment currently in the changeover posi-
tion (marked by an arrow, see Fig. 5.2 - 5
). 5
Å Activate the One nozzle radio button.
Å Click the button for the required function.
The dialog box shown below is then displayed.
5
Å In the entry field, enter the number of the required segment, and confirm with OK. The function
is then carried out for the selected nozzle.
5
User Manual HS-50 5 Single Functions
Software Version SR.501.xx 12/99 Issue US 5.2 Single functions, Gantry
167
t IIt
All nozzles
If this radio button is activated, the selected function i.e."Return", "Pick up" or "Remove" is carried
out for all nozzles on the revolver head. 5
Å Activate the All nozzles radio button.
Å Click the button for the required function.
The function is carried out for all functions on the revolver head.
Return 5
When this function is activated, the nozzles are returned to the correct magazine of the nozzle
changer (or the nozzle on the selected segment is returned to its magazine).
Å Click the Return button.
If the "All nozzles" radio button is activated, the function is carried out immediately.
If the "One nozzle" radio button is activated, a dialog box is opened for you to enter the number
of the required segment (see page 166
).
Remove 5
When this function is activated, all nozzles or the nozzle on the specified segment are discarded
into the reject container.
Å Click the Remove button.
If the "All nozzles" radio button is activated, the function is carried out immediately.
If the "One nozzle" radio button is activated, a dialog box is opened for you to enter the number
of the required segment (see page 166
).
Pick up 5
When this function is activated, nozzles specified for current use are picked up from their respec-
tive magazines (or a nozzle is picked up for the specified segment).
Å Click the Pick up button.
If the "All nozzles" radio button is activated, the function is carried out immediately.
If the "One nozzle" radio button is activated, a dialog box is opened for you to enter the number
of the required segment (see page 166
).
Replace 5
This function is used to replace the nozzle on the specified segment with one of the same type.
Å Click the Replace button.
A dialog box opens to allow you to enter the segment number.
(The rest of the procedure is described on page 166
).