User Manual HS-50 3 Introduction and Basic Concepts Software Vers ion SR.501.xx 12/99 Issue US 3.1 Mac hine Displays a nd Controls 99 t I I t 3.1.3.1 Functions General Operati ng Statuses: 3 – Operating indicator li ght …

100%1 / 414
3 Introduction and Basic Concepts User Manual HS-50
3.1 Machine Displays and Controls Software Version SR.501.xx 12/99 Issue US
98
t IIt
WARNING
Only appropriately qualified personnel are permitted to use the key-operated switch for service or
maintenance work. The key must be removed to prevent unauthorized access as otherwise seri-
ous injury to personnel or damage to the machine may occur. 3
3
3.1.3 Main Fault Indicator
The main fault indicator (see Figure 3.1 - 1) contains 2 fault indicator lights (white) together with
an operating indicator light (green)
The operating indicator light is located between the two fault indicator lights. This indicates
whether the machine is in production or wait mode.
The nature and location of any malfunction can be identified using the operating indicator light
(flashing, glowing etc.) and the two fault indicator lights.
The following section describes the information provided by the two fault indicator lights.
NOTE
The operating statuses (or their meanings) of the two fault indicator lights can be individually pro-
grammed to respond to local circumstances (see the description of the "Programmable Operating
Statuses" in the next section). 3
3
3
3
User Manual HS-50 3 Introduction and Basic Concepts
Software Version SR.501.xx 12/99 Issue US 3.1 Machine Displays and Controls
99
t IIt
3.1.3.1 Functions
General Operating Statuses: 3
Operating indicator light continuously illuminated
The machine is operating.
Operating indicator light flashes
The machine is waiting for a PCB in the input conveyor or is waiting for the output conveyor to
become free.
Fault light flashes
One or more tracks are empty at the feeder location of the gantry in question.
However, the machine will process any components present.
Fault light continuously illuminated
An error has occured at the gantry in question--> the machine has stopped.
Both lights continuously illuminated
An error has occurred which affects the entire machine--> the machine has stopped.
3
Programmable Operating Statuses: 3
Table 3.1 - 1 shows the operating states which have been programmed in the standard configuration
(version as delivered) together with the meaning these states have with regard to the main fault in-
dicator. 3
NOTE 3
The entries in the table next to "flashes" refer to the frequency with which the relevant lamp flashes
for a given event.
The entry (1, 5), for example, can be explained as follows: 3
The first number in the brackets indicates the time, expressed in 100 msec intervals, for which
the fault indicator lamp is switched on, i.e. 1 x 100 msec in the above example.
The second number in the brackets indicates the time, expressed in 100 msec intervals, for
which the fault indicator lamp is switched off, i.e. 5 x 100 msec in the above example.
NOTE
The file containing the parameters for configuring the main fault indicator is located in the directory
containing the machine files on the station computer. Changes to the parameters in this file must
be made by suitably qualified staff only. 3
3 Introduction and Basic Concepts User Manual HS-50
3.1 Machine Displays and Controls Software Version SR.501.xx 12/99 Issue US
100
t IIt
3
L1
(Top lamp)
L2
(Middle lamp)
L3
(Bottom lamp)
Meaning
Status display
flashes (1,10) flashes (7,7) flashes (1,10) Reference run
unchanged flashes (1,5) unchanged Waiting until axes in position
unchanged flashes (7,7) unchanged Waiting for setup data
unchanged flashes (7,7) unchanged Waiting for cluster data
unchanged flashes (7,7) unchanged Load table program
unchanged flashes (7,7) unchanged Position recognition
unchanged flashes (1,10) unchanged Ink spot recognition
unchanged flashes (7,7) unchanged Nozzle configuration test
unchanged flashes (7,7) unchanged Feeder posn. recogn.
unchanged flashes (7,7) unchanged One track is empty
unchanged flashes (7,7) unchanged No further track available
unchanged flashes (7,7) unchanged Go to refill position
unchanged flashes (7,7) unchanged Transport being initialized
unchanged flashes (7,7) unchanged Place PCB in input conveyor
flashes (1,10) flashes (7,7) unchanged Remove PCB from output conveyor
unchanged flashes (7,7) flashes (1,10) Remove PCB in output conveyor 2
flashes (1,10) flashes (7,7) flashes (1,10) Width adjustment
unchanged flashes (1,10) unchanged Transport PCB
flashes (1,10) flashes (7,7) flashes (1,10) Both output conveyors are cleared
on flashes (1,10) on Transport errors
on off on Go to service position
on Placement
flashes (1,20) Waiting for processing data
Error display
on off unchanged Machine error, right
on off unchanged Track empty, right
on off unchanged Nozzle configuration, right
on off unchanged Transport error, right
on off on Fiducial error, left and right
on off on Fiducial error, left and right
unchanged off on Track empty, left
unchanged off on Nozzle configuration, left
unchanged off on Transport error, left
unchanged off on Machine error, left
Pick-up error display
unchanged unchanged flashes (1,20)
First track empty, left
unchanged unchanged flashes (5,20)
Further tracks empty, left
unchanged unchanged flashes (5,5)
Penultimate track in use, left
unchanged unchanged flashes (1,2)
Last track in use, left
flashes (1,20) unchanged unchanged
First track empty, right
flashes (5,20) unchanged unchanged
Further tracks empty, right
flashes (5,5) unchanged unchanged
Penultimate track in use, right
flashes (1,2) unchanged unchanged
Last track in use, right
Tab. 3.1 - 1 Standard configuration for the main fault indicator