00191369-02.pdf - 第251页
User Manual HS-50 6 Vision functions Software Version S R.501.xx 12/99 Issue US 6.6 Test Comp onent 251 t I I t 6.6.3 Select Pa ckage For m Menu If you s elect th e T est component opti on in the Main view menu, the fol …

6 Vision functions User Manual HS-50
6.6 Test Component Software Version SR.501.xx 12/99 Issue US
250
t IIt
6
Fig. 6.6 - 8 ’Test component’ flow chart, LEAD, GRID, and BALL meas. modes
’Test component’ menu options
’LEAD’, ’GRID’, and ’BALL’ measure mode menus
’LEAD measure mode’ menu ’
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement Window
Separately
for each pin
Combined
windows
Cancel Accept
Number of
balls to be
measured
Cancel Accept
Fast
Robust
Measurement Evaluation
Position
and
existance
Quality
Cancel Accept
’GRID measure mode’ menu ’BALL measure mode’ menu

User Manual HS-50 6 Vision functions
Software Version SR.501.xx 12/99 Issue US 6.6 Test Component
251
t IIt
6.6.3 Select Package Form Menu
If you select the Test component option in the Main view menu, the following actions will occur: 6
– The functions for the vision system are activated in the station computer
– The Select package form menu will drop down.
– The station computer will determine the package form numbers list with commentaries from
the set-up.
6
Fig. 6.6 - 9 Select package form menu
The menu allows you to choose between the following options, as the diagram shows: 6
– Selection of the camera types (80F machines only).
– Load GF data
– Save GF data
NOTE 6
Buttons are active when the text on the button is black (rather than gray). This means that you
can launch the associated function by clicking on the button with the mouse.

6 Vision functions User Manual HS-50
6.6 Test Component Software Version SR.501.xx 12/99 Issue US
252
t IIt
The Load GF data button will, for example, only be active if you have previously clicked on a
package form in the lists field.
The Save GF data button will only be active if you have changed the package form parameters.
You can switch from the ’Test component ’ menu to the Main menu at any time in order to start
actions such as "Fill track" etc. The settings in the ’Test component’ menu will be retained, which
means that the same conditions will be set up when you return to the ’Test component’ menu. 6
However, if you have changed the fiducial data or taught a new fiducial, and then switch from the
Main menu to the ’Test component’, ’Single functions’, ’SITEST’ or ’Continue placement’ menu,
the ’Save fiducial data’ selection box will appear when you leave the ’Teach fiducial’ option. You
can then either save the modified or new data or delete it. 6
By selecting the Save GF data option you cause the station computer to send the package form
data to the line computer, where it is saved. The modified package form data is updated in the
remaining stations as well. The next time a cluster is loaded the modified GF data is sent to all
stations in the line. 6
6
Fig. 6.6 - 10 Save GF data option box