6 Vision functions User M anual HS-50 6.6 Test Component Software V ersion SR.501.xx 12/99 Issue U S 242 t I I t Å Sa ve GF data The genera ted package f orm paramete rs will be sa ved wh en you c lick on this b utton. –…

User Manual HS-50 6 Vision functions
Software Version SR.501.xx 12/99 Issue US 6.6 Test Component
241
t IIt
6.6 Test Component
6.6.1
Test Component
Flow Chart
The Test component flow chart shows in graphic form all menu options together with their sub-
functions. The menus are indicated by being bordered with a solid line, while the option boxes use
a dash-dotted line and the input boxes a dotted line. 6
6.6.2 Information on the
Test Component
Flow Chart
6.6.2.1 Menus
The Test component option includes the following menus: 6
– Select package form
– Test component
The Save component name option box will drop down every time you wish to quit the Test com-
ponent menu, having previously generated or modified GF data. This gives you the choice of ei-
ther saving or discarding the GF data in question. 6
You can quit the individual menus by clicking on either the icons of another menu or on the Main
view icon. 6
6.6.2.2 Input Boxes, Option Boxes
For data input, displaying values and initiating actions the system offers the following input boxes:6
– Measure mode
– Adjust contrast sensitivity
– Select component type (80F
4
, 80F
4
-6 or 80F
5
machines only)
You can quit the input boxes by clicking on OK, Accept or Cancel. 6
Å Click on OK or Accept to have the program save the data. The box will then close.
Å Click on the Cancel button to discard the data, after which the input box will close.
6.6.2.3 Buttons
The system provides the following buttons for selecting options: 6
Å Load GF data
Once you have selected the component you want from the lists field, click onto the Load GF
data button. The package form parameters will be loaded.

6 Vision functions User Manual HS-50
6.6 Test Component Software Version SR.501.xx 12/99 Issue US
242
t IIt
Å Save GF data
The generated package form parameters will be saved when you click on this button.
– Pick up
The placement head picks up the selected component.
6.6.2.4 Video Images
In certain situations, the camera image of the MVS system (vision analysis unit) is displayed on
the screen of the station computer. The screen will also contain a header and footers: 6
– The header may contain, for example, the currently selected menu option, the package form
number, analysis criteria, measurement results, and so on.
– The footers will contain command sequences, keyboard commands, camera coordinates and
so on.
You can always quit video image screens by pressing the Esc key. The current menu window will
then reappear. 6
6.6.2.5 Messages
Messages are text fields which contain information regarding actions, warnings and so on. They
will appear under the following circumstances: 6
– incorrect operator actions.
– requests to the operator to carry out certain actions (for example, input package form number).
– information (for example, board is being disposed of).
– to indicate the system is busy performing an action (for example, package form data being
saved).

User Manual HS-50 6 Vision functions
Software Version SR.501.xx 12/99 Issue US 6.6 Test Component
243
t IIt
6
Fig. 6.6 - 1 ’Test component’ flow chart - ’Test component’ menu option’
’Test component’ menu options
Main view
Main view menu
Setup
Error
Feeders
Gantry 3 functions
Gantry 4 functions
PCB transport 2
PCB transport 1
Teach fiducial
Test component
SITEST
GEM
Main view
Markenauswahl
Test component
Save
GF data
Test component
menu option
Select package form
Package form
edited?
No
Gantry 1 functions
Gantry 2 functions
Yes
Discard
component
Package
form is saved
Yes
No
Package
form is
restored
Yes
’Save edited GF data’
option box