00191369-02.pdf - 第387页
User Manual HS-50 11 S tation extensions / hardware Software Version S R.501.xx 12/99 Issue US 11.2 Component barcode 387 t I I t 1 1.2 Component barcode 1 1.2.1 General With the HS- 50 placem ent syste m, a barcod e rea…

11 Station extensions / hardware User Manual HS-50
11.1 HS-50 nozzle changer Software Version SR.501.xx 12/99 Issue US
386
t IIt
11.1.5 Position detection
There is a position detection fiducial on every magazine. 11
11
Fig. 11.1 - 3 Nozzle changer - position detection
Key to Fig. 11.1 - 3
(1) Positioning fiducial
(2) Position of the nozzles in the magazine with respect to the positioning fiducial
11
Å See section 6 "Vision functions" for the use of fiducials.

User Manual HS-50 11 Station extensions / hardware
Software Version SR.501.xx 12/99 Issue US 11.2 Component barcode
387
t IIt
11.2 Component barcode
11.2.1 General
With the HS-50 placement system, a barcode reader can be used to check that the track allocation
is correct and to read component data from component reels. A barcode reader is attached to both
of the operating panels on the placement system. 11
11
Fig. 11.2 - 1 Component barcode reader
Key to Fig. 11.2 - 1
(1) Barcode reader
(2) Operating panel, right
(3) Operating panel, left
T PCB transport direction 11

11 Station extensions / hardware User Manual HS-50
11.2 Component barcode Software Version SR.501.xx 12/99 Issue US
388
t IIt
Track allocation 11
Four-digit barcode strips are attached to the lateral safety screens for the purposes of track allo-
cation. The first digit is used to identify the component table (1, 2, 3 or 4), while the remaining three
digits specify the track number. There are also return barcodes at both ends of the barcode strip.
The barcode strips are numbered consecutively in intervals of two (1, 3, 5, 7...) and each repre-
sents 2 tracks (barcode 1 = track 1 and 2). 11
Components 11
Data can be read from the component reels to compare the stock of components against the
quantity specified in the set-up file (refill check), for example. 11
An audible signal is given when each dataset has been read successfully. 11
PLEASE NOTE 11
The component barcode reader option must be configured on the line computer.
Barcodes that start with the number 1, 2, 3 or 4 and are four digits long are interpreted as track
barcodes. All other barcodes that do not start with number 1, 2, 3 or 4 are regarded as compo-
nent barcodes.