OM-1606 6-4 6. Splicing 6.3. Indication of "Alarm for Splicing" on the Machine Information Window 6.3.1 Characteristics of the T ape Feeders applicable to the Splicing Operation "Alarm for Splicing" D…

100%1 / 235
OM-1606
6. Splicing
6-31011-003
(4) Set the timing to indicate the "Splicing Warning".
Specied with [Tape Length (mm)]
Note
The "Splicing Warning" is not indicated with a remaining tape length of
900 mm or less.
(4.1) Select "Tape Length" in the Warning Mode "90 mm + Condition"
text box.
(4.2) Press the [Count] button.
(The "Count" input window will appear.)
"Count" Input Window FF3
(4.3) Enter the tape length.
Input Range
: 0 to 9999 mm
(4.4) Press the [Set] button to dene the entered values.
Specied with [PCB Count]
(4.1) Select "PCB Count" in the Warning Mode "90 mm + Condition" text
box.
(4.2) Press the [Count] button.
(The "Count" input window will appear.)
(4.3) Enter the number of PCBs to be produced.
Input Range
: 0 to 9999 PCBs
(4.4) Press the [Set] button to dened the entered values.
(5) Press the [Apply] button.
(The entered values will be applied.
When the [Cancel] button is pressed, the set values are cancelled.)
OM-1606
6-4
6. Splicing
6.3. Indication of "Alarm for Splicing" on the Machine
Information Window
6.3.1 Characteristics of the Tape Feeders applicable to the Splicing
Operation
"Alarm for Splicing" Display FF4
Procedure
(1) Conrm the contents on the machine information window and press the [OK]
button.
(The "Machine Information" window will be closed.)
1009-002
OM-1606
6. Splicing
6-5
(2) Press the [Comp. Reld.] button in the AUTO. OPN. submenu window.
(The "Comp. Reload" window will appear.)
Example of "Comp. Reload" Window FF5
Note
The displayed contents will differ depending on selection of the options.
Reference
Refer to SIGMA-G4/G5 main machine instruction manual, "Volume 2, Chapter 1,
3. Comp. Reload" for details.
(3) Conrm the tape feeder where the splicing operation is required.
(3.1) Press each block button in the "Select block" section or the [ALL]
button.
(The feeder data items will be displayed in the Feeder List.)
(3.2) Press the appropriate Fdr. No. and conrm the contents in the [4]
Component type.
1009-003