OM-1606-006w_GT-28x.pdf - 第61页
OM-1606 2. Attachment and Detachment of T ape 2-29 2.7 Handling of Magnet Plate for 8 mm Width T ape In the 8 mm width dual feeder, the Magnetic Plate is attached to the chute section to stabilize the component pick-up c…

OM-1606
2-28
2. Attachment and Detachment of Tape
2.6 Joint Detection Unit
In the case of tape feeders GD-28080, GD-28081, GD-28082, GD-28083,
GD-12162, GD-24322, GD-44562, GD-72002 and GD-88002 with Joint detection
units, pass the tape through the joint detection unit.
Procedure
(1) Bend the cover tape at the end of the tape and pass the tape according to the
tape guide from under the joint detection unit.
Pass the tape from
the lower side
Bend the cover tape at the end of tape
Tape guide
GD-28080, GD-28081, GD-28082, GD-28083 Joint Detection Unit FB35
Note
If a 16 mm width tape in GD-12162, 32 mm width tape in GD-24322 and 56
mm width tape in GD-44562 is to be attached, it is necessary to move the tape
guide of the joint detection unit.
Move the tape guide
Tape Guide Set Screw
Tape Guide
Move the tape guide
Tape Guide Set Screw
Tape Guide
GD-12162 Joint Detection Unit FB36 GD-24322, GD-44562, (Illustration of GD-24322)
Joint Detection Unit FB37
1011-003

OM-1606
2. Attachment and Detachment of Tape
2-29
2.7 Handling of Magnet Plate for 8 mm Width Tape
In the 8 mm width dual feeder, the Magnetic Plate is attached to the chute section
to stabilize the component pick-up condition.
The effect of the magnetism varies, depending on the component type, size, and
material.
Also, for some components, the magnetism might have harmful effects on the
component characteristics or pick-up conditions.
Note
Check the effect of the magnetism on the components and if it has any adverse
effect, remove the Magnetic Plate.
2.7.1 How to remove the Magnetic Plate for 8mm Width Tape
Procedure
(1) Loosen the set screw (round head screw) to remove the magnetic plate, and
attach it onto the magnetic plate housing section.
Housing (There is also a housing
section on the opposite side).
Set Screw
(Round Head Screw)
Set Screw
(Round Head Screw)
Magnetic Plate
Magnetic Plate
Magnetic Plate housing section
FB38
1005-002

OM-1606
2-30
2. Attachment and Detachment of Tape
Notice
House the magnetic plate paying attention to its front and rear, so
that the magnetic plate does not stick out from the cover, as shown
in FB39.
Correct:
The magnetic plate is housed under the cover.
Incorrect:
The magnetic plate sticks out of the cover.
FB39
0908-001