5OM-1011-002.pdf - 第57页

Section5 Electrical Circuit Diagram Interlock Board IN 1-1 0305-001A (M805WBB--0004) 5-14 Tg0861-PM-MD XA-Axis Alarm Y A-Axis Alarm XB-Axis Alarm YB-Axis Alarm LA1-Axis Alarm LA2-Axis Alarm LB2-Axis Alarm LB1-Axis Alarm …

100%1 / 185
Section5 Electrical Circuit Diagram
I/O Board 1-3
0305-001- (M805WBB--0003) 5-13 Tg0861-PM-MD
LA1-Axis Vaccum/Blow
LA2-Axis Vaccum/Blow
LA1-Axis and LA2-Axis
Source Blow Pressure
Open/Close
LA1-Axis Vaccum
Sensor Reference
LA2-Axis Vaccum
Sensor Reference
Safety Cover
Electromagnetic Lock A
Supply Cover
Electromagnetic Lock A
Reserved
LB1-Axis Vaccum/Blow
LB2-Axis Vaccum/Blow
LB1-Axis and LA2-Axis
Source Blow Pressure
Open/Close
LB1-Axis Vaccum
Sensor Reference
LB2-Axis Vaccum
Sensor Reference
Safety Cover
Electromagnetic Lock B
Supply Cover
Electromagnetic Lock B
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
LA1-Axis Vaccum
Sensor Reference
LA2-Axis Vaccum
Sensor Reference
LB1-Axis Vaccum
Sensor Reference
LB2-Axis Vaccum
Sensor Reference
MB (A) Block
G Block
C (B) Block
MB (B) Block
MC (B) Block
MC (A) Block
G Block
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Section5 Electrical Circuit Diagram
Interlock Board IN 1-1
0305-001A (M805WBB--0004) 5-14 Tg0861-PM-MD
XA-Axis Alarm
YA-Axis Alarm
XB-Axis Alarm
YB-Axis Alarm
LA1-Axis Alarm
LA2-Axis Alarm
LB2-Axis Alarm
LB1-Axis Alarm
XA-Axis Limit (+)
XA-Axis Limit (-)
XB-Axis Limit (+)
XB-Axis Limit (-)
YA-Axis Limit (+)
YA-Axis Limit (-)
YB-Axis Limit (+)
YB-Axis Limit (-)
Note:
The area surrounded by the dashed line belongs to the relay P.C.B. (UA18 & UA19).
LA1-Axis Limit (+)
LA1-Axis Limit (-)
LA2-Axis Limit (+)
LA2-Axis Limit (-)
LB2-Axis Limit (+)
LB2-Axis Limit (-)
LB1-Axis Limit (+)
LB1-Axis Limit (-)
BPC-Axis Limit (+)
BPC-Axis Limit (-)
LA1-Axis Nozzle
Excessive Pushing Detection
LA2-Axis Nozzle
Excessive Pushing Detection
LB2-Axis Nozzle
Excessive Pushing Detection
LB1-Axis Nozzle
Excessive Pushing Detection
Beam Emergency Stop 1
(PAUSE)
Load Power Supply
Shut-Off Detection
Section5 Electrical Circuit Diagram
Interlock Board IN 1-2
0305-001- (M805WBB--0005) 5-15 Tg0861-PM-MD
Air Pressure Drop
Detection
LA1-Axis Level
Detection (1)
LA1-Axis Level
Detection (2)
LA1-Axis Level
Detection (3)
LA1-Axis Level
Detection (4)
LA2-Axis Level
Detection (1)
LA2-Axis Level
Detection (2)
LA2-Axis Level
Detection (3)
LA2-Axis Level
Detection (4)
LB2-Axis Level
Detection (1)
LB2-Axis Level
Detection (2)
LB2-Axis Level
Detection (3)
LB2-Axis Level
Detection (4)
LB1-Axis Level
Detection (1)
LB1-Axis Level
Detection (2)
LB1-Axis Level
Detection (3)
LB1-Axis Level
Detection (4)
Beam Approach
Detection
Lifted Nozzle Detection
A1
Lifted Nozzle Detection
A2 (Option)
Lifted Nozzle Detection
B1
Lifted Nozzle Detection
B2 (Option)
YA-Axis Startionary
Position Stopper
Backward Limit
YB-Axis Startionary
Position Stopper
Backward Limit
Beam A Power Supply
Shut-Off Detection
Beam B Power Supply
Shut-Off Detection
Maintenance Cover A
Detection
Maintenance Cover B
Detection
Maintenance Opening
Section Detection A
Maintenance Opening
Section Detection B
BPC-Axis Alarm
2A1-Axis Alarm (Reserved)
Note:
The area surrounded by the dashed line belongs to the relay P.C.B. (UA18 & UA19).
MB (A)
Block
MC (A)
Block
MC (B)
Block
MB (B)
Block
C (A)
Block
F(A1)
Block
F (B1)
Block
Connecter Board