APC SOFTWARE SETUP AND RECOMMENDED SETTINGS
DIAGNOSTICS
Chapter Issue 1 Nov 16 All Purpose Clamping (APC) Manual 2.9
Toggle OTS Mid
Plate Up
This functionality controls the mid plate operation Up.
NOTE
If both the mid plate up and mid plate down are ON or both are OFF the mid
plate is uncontrolled.
Toggle OTS Z
Clamps
This functionality toggles the Z clamps ON/OFF.
NOTE
With the Z clamps toggled ON, toggling the mid plate up or down will have no
effect.
Cycle OTS Z
Clamps
This functionality cycles the Z clamps.
Cycle OTS Over Top
Clamp
This functionality moves the top clamp forward and backward in a repeating
cycle.
Cycle OTS Mid Plate
Up and Down
This functionality moves the mid plate up and down in a repeating cycle.
Cycle OTS Clamps This functionality allows all of the parts in the APC to move in a repeating cycle,
synchronised together.
NOTE
The system sets the number of cycles to be performed from the cycle count;
when the number of cycles is reached the diagnostic stops.
Using the Adjust button, the following can be set:
• Board Width
•Clamp Pressure
• Snug Pressure
• Retain Board
• Cycle Count (from 1 to 999999)
APC SOFTWARE SETUP AND RECOMMENDED SETTINGS
DIAGNOSTICS
2.10 All Purpose Clamping (APC) Manual Chapter Issue 1 Nov 16
A3 DRAWINGS
ELECTRICAL DRAWINGS
Chapter Issue 1 Nov 16 All Purpose Clamping (APC) Manual 3..1
CHAPTER 3 A3 DRAWINGS
ELECTRICAL DRAWINGS
Description Drawing No. Sheets Issue State
Circuit Diagram APC 220329 1 02
Circuit Diagram Pneumatic 222966 1 02