SIPLACE 80S-20/F4/F4-6/F5 Service Manual 1 Operational Safety
Edition 04/98 1.2 Safety equipment
1 - 19
Fig. 1.2.5 SIPLACE 80S-20/F
4
/F
4
-6/’F
5
safety circuits
Start button pressed
Emergency stop button
pressed?
Protective cover open ?
Key switch
closed (position
I
)?
No
Component table safety
circuit interrupted?
Yes
No
No
Yes
Yes
No
$FWLYH
K1 *) Yes
K2 *) Yes
9ROWDJH
y axis 100 V
x axis 100 V
Star axis 100 V
dp axis 30 V
z axis 30 V
$FWLYH
PCB conveyor Yes
PCB clamping deviceYes
Width adjustment Yes
PCB stopper Yes
Tape cutter Yes
Yes
$FWLYH
K1 *) No
K2 *) Yes
9ROWDJH
y axis 0 V
x axis 0 V
Star axis **) 10 V
dp axis 30 V
z axis 30 V
$FWLYH
PCB conveyor Yes
PCB clamping device No
Width adjustment Yes
PCB stopper No
Tape cutter No
$FWLYH
K1 *) No
K2 *) No
9ROWDJH
y axis 0 V
x axis 0 V
Star axis **) 10 V
dp axis 30 V
z axis 30 V
$FWLYH
PCB conveyor No
PCB clamping device No
Width adjustment No
PCB stopper No
Tape cutter No
*) K1, K2 protective contactor combination
**) The maximum current is limited by a 4.7 Ohm resistor.
Compressed air
min. 5.1 bar?
Yes
No
1 Operational Safety SIPLACE 80S-20/F4/F4-6/F5 Service Manual
1.2 Safety equipment Edition 04/98
1 - 20
1.2.5 Guard on the component table locations
DANGER OOO
All locations must be equipped with feeders in order to guarantee operational reliability. If there are not
enough conveyors available, a guard ("feeder dummy") must be fitted in place of the conveyor.
The following variants can be used:
Item no. 00116820-01 SIPLACE guard for 1 location
Item no. 00116821-01 SIPLACE guard for 6-10 locations
Item no. 00116822-01 SIPLACE guard for 11-20 locations
Fig. 1.2.6 Guard
-Key to Fig. 1.2.6
1 Guard for 1 location 2 Guard for 6-10 locations
3 Guard for 11-20 locations
SIPLACE 80S-20/F4/F4-6/F5 Service Manual 1 Operational Safety
Edition 04/98 1.3 Residual voltages in the servo unit and discharge times when placement system is switched off
1 - 21
 5HVLGXDOYROWDJHVLQWKHVHUYRXQ LWDQGG LVFKDUJH
WLPHVZKHQSODFHPHQWV\VWHPLVVZ LWFK HGRII
When the emergency stop button is pressed or the placement system is switched off, the electrolytic capaci-
tors quickly discharge to safe residual voltage levels via switched resistors on the discharge board
(00308443-xx).
The voltages can be tapped off at test sockets 001 - 009 on the voltmeter unit in the servo unit.
DANGER
Automatic placement systems from the SIPLACE family are powered with 3 x 400 V ± 10 %, 50/60 Hz mains
voltage.
This means that parts of the system carry potentially fatal voltages - even when switched off at the main
switch.
Death, serious injury or considerable damage may result if these placement systems are handled incorrectly.
Always follow the applicable accident prevention and VDE regulations (particularly VDE 0113).
The guard over the servo unit must ONLY be opened by appropriately qualified and trained personnel.
Fig. 1.3.1 Test sockets on the voltmeter unit in the servo unit
un-
switched
switched
Servo
unit