00191494-01.pdf - 第10页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 8 63 X-axis disabled CAUSE ● X-axis switched off at the axis contro ller switch. REMEDY ● X-axis should be switch ed on at the a…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
7
52 BERO SZ2 not being actuated
CAUSE
● Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
● Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
● Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration
of the motor control board not optimal.
REMEDY
● Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
● Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
● Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X-axis does not reach setpoint position
CAUSE
● Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
● Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y-axis does not reach setpoint position
CAUSE
● Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
● Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z-axis does not reach setpoint position
CAUSE
● Cam disk in incorrect position at zero pulse; motor defective; Z-axis jamming.
REMEDY
● Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry
out axis calibration; fit spare placement head.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
8
63 X-axis disabled
CAUSE
● X-axis switched off at the axis controller switch.
REMEDY
● X-axis should be switched on at the axis controller switch.
64 Y-axis disabled
CAUSE
● Y-axis switched off at the axis controller switch.
REMEDY
● Y-axis should be switched on at the axis controller switch.
65 D1-axis disabled
CAUSE
● DP1-axis switched off at the axis controller switch.
REMEDY
● DP1-axis should be switched on at the axis controller switch.
66 D2-axis disabled
CAUSE
● DP2-axis switched off at the axis controller switch.
REMEDY
● DP2-axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
● Star axis switched off at the axis controller switch.
REMEDY
● Star axis should be switched on at the axis controller switch.
68 Z-axis disabled
CAUSE
● Z-axis switched off at the axis controller switch.
REMEDY
● Z-axis should be switched on at the axis controller switch.
75 Programmed position of Z-axis outside travel range
CAUSE
● Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
● Check the machine data in the line computer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
9
79 Arm for turning station 1 has not swivelled out
CAUSE
● Feed motor defective; proximity switch defective.
REMEDY
● Replace feed motor; carry out axis calibration; fit new proximity switch.
80 Arm for turning station 2 has not swivelled out
CAUSE
● Feed motor defective; proximity switch defective.
REMEDY
● Replace feed motor; carry out axis calibration; fit new proximity switch.
94 DETERMINANT not correct during position recognition
CAUSE
● The two fiducials of a circuit image are on one position; the three fiducials of a circuit image are in
a line.
REMEDY
● Correct placement program in the line computer.
95 Fiducial missing in position recognition
CAUSE
● Fiducial quality of a fiducial not adequate; PCB transport adjusted imprecisely; camera illumina-
tion defective; search field too small.
REMEDY
● Clean fiducial; reteach fiducial (increase size of search field); check conveyor width; check stop-
per setting.
96 CORR_MOVE not correct during position recognition
CAUSE
● The two fiducials of a circuit image are on one position.
REMEDY
● Correct placement program in the line computer.
101 Track empty, no component during pick-up
CAUSE
● On a single track at least three pick-up errors occurred immediately after one another; no compo-
nent in the pick-up position; set up for incorrect component (e.g. cubic instead of non-cubic).
feeder jamming; cover foil parted.
REMEDY
● Refill components and reset track; check set-up.
get feeder working properly again.