00191494-01.pdf - 第32页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 30 301 Communication to vision sys tem defective (Error code - 2) CAUSE ● System error REMEDY ● Reset system. 302 Communication …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
29
294 Communication to vision system defective (Error code -9)
CAUSE
● System error
REMEDY
● Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
● System error
REMEDY
● Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
● System error
REMEDY
● Reset system.
297 Communication to vision system defective (Error code -6)
CAUSE
● System error
REMEDY
● Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
● System error
REMEDY
● Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
● System error
REMEDY
● Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
● Timeout during request to vision system (MVS / M10000).
REMEDY
● Reset vision system; at M10000 check V24 connection between MC and M10000.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
30
301 Communication to vision system defective (Error code -2)
CAUSE
● System error
REMEDY
● Reset system.
302 Communication to vision system defective (Error code -1)
CAUSE
● System error
REMEDY
● Reset system.
303 Communication to vision system defective (Error code 0)
CAUSE
● System error
REMEDY
● Reset system.
304 Communication to vision system defective (Error code 1)
CAUSE
● System error
REMEDY
● Reset system.
311 Undefined error number from vision system (Error code 2)
CAUSE
● System error
REMEDY
● Reset system.
312 Coplan.: Component description has too many groups
CAUSE
● Package form data erroneous.
REMEDY
● Check package form data and respecify set-up.
313 Coplan.: Component number invalid
CAUSE
● No component description exists for the component to be measured
REMEDY
● Check set-up and respecify.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
31
314 CRDL not initialized, test not possible
CAUSE
● Incorrect command sent to tester.
REMEDY
● If electrical testing is not possible, reset tester.
315 CRDL internal error (Error code 11H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
316 CRDL internal error (Error code 12H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
317 CRDL internal error (Error code 13H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
318 CRDL internal error (Error code 14H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
319 Format error of selected component in SMD data record (15H)
CAUSE
● Erroneous CRDL component description
REMEDY
● Check data record for CRDL test in the component description in the line computer and correct if
necessary.
320 Format error in measurement request (Error code 16H)
CAUSE
● Incorrect command sent to tester.
REMEDY
● If electrical testing is not possible, reset tester.