00191494-01.pdf - 第22页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 20 221 Programmed position of X-ax is outside travel range CAUSE ● Error in the local machin e data (location fiducials). REMEDY…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
19
214 Check sum error of answer from coplanarity
CAUSE
● Error in the response from coplanarity.
REMEDY
● Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
216 Position control of X-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
217 Position control of Y-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
● The first character of the answer from coplanarity is lost.
REMEDY
● Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
● Too many measurement data for one component
REMEDY
● Inform Siemens Service.
220 Coplanarity cannot execute command
CAUSE
● Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
● Switch machine off and back on; respecify set-up; check package form data.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
20
221 Programmed position of X-axis outside travel range
CAUSE
● Error in the local machine data (location fiducials).
REMEDY
● Check the fiducial data in the machine data.
222 Programmed position of Y-axis outside travel range
CAUSE
● Error in the local machine data (location fiducials).
REMEDY
● Check the fiducial data in the machine data.
226 Vacuum of pick-up circuit not within range
CAUSE
● Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
● Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
● Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
● Maintain segments; check vacuum; extend limits; check vacuum circuit.
228 Interface signals to the preceding station incorrect
CAUSE
● Interface line not connected; cable defective; interface boards defective.
REMEDY
● Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
● PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
● PCB board jamming; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
21
231 No PCB on the input conveyor
CAUSE
● The PCB board was removed while being transported onto the central conveyor; sensor defec-
tive.
REMEDY
● Under the menu "Transportation error" continue placement, place board on input conveyor; fit
new sensor.
232 The lifting table cannot be moved downwards
CAUSE
● Beros defective; cutout triggered.
REMEDY
● fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
● Package form data, set-up erroneous.
REMEDY
● Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
● Beros defective; cutout triggered.
REMEDY
● Fit new Beros; close lifting table cutout.
235 Center conveyor light barrier is not released
CAUSE
● PCB board jamming in the central conveyor; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
● PCB board jamming in the center conveyor; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
● Compressed air lacking; back pressure too high; stopper defective.
REMEDY