Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 65 694 Incorrect nozzle length CAUSE ● No nozzle present. The nozzle is seated incorrect ly . The wrong nozzle type has b een se…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
64
574 Feeder position recognition not possible
CAUSE
● Conveyor fiducials are outside the travel range of the main axes
REMEDY
● Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
● Incorrect entry in the line computer GF editor.
REMEDY
● Change the processing data for the package form in the line computer GF editor.
576 Incorrect placement sequence in cluster data
CAUSE
● Inconsistency in the cluster data
TO RECTIFY
● Generate a new placement sequence on the line computer. Notify Siemens Service.
578 Nozzle not ejected into rejects box
CAUSE
● The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
● Use the SITEST program to record the x, y and z nozzle positions.
Remove the obstacle or empty the rejects box.
579 Coplan: Bad component, to be returned
CAUSE
● Lead height outside tolerance.
TO RECTIFY
● Discard the component.
580 Copl: Comp. cannot be measured (ex. offset)
CAUSE
● Coplanarity measurement not possible due to results of optical centering measurement.
TO RECTIFY
● Discard the component.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
65
694 Incorrect nozzle length
CAUSE
● No nozzle present.
The nozzle is seated incorrectly.
The wrong nozzle type has been set up.
REMEDY
● Make sure the head is fitted with the correct nozzle.
Check the seating of the nozzle.
696 Warning: Break to DP1-axis
CAUSE
● Internal program run error when the DP1-axis is overshooting.
REMEDY
● Confirm the error message.
If this error occurs frequently, please notify Siemens Service
697 Warning: Break to DP2-axis
CAUSE
● Internal program run error when the DP1-axis is overshooting.
REMEDY
● Confirm the error message.
If this error occurs frequently, please notify Siemens Service
698 Error during break to DP1-axis: boot!
CAUSE
● It is not possible to confirm error message 696 with respect to the internal program run error.
REMEDY
● Reboot the station. Notify Siemens Service.
699 Error during break to DP2-axis: boot!
CAUSE
● It is not possible to confirm error message 697 with respect to the internal program run error.
REMEDY
● Reboot the station. Notify Siemens Service.
701 BO: Info received is not a message (ident/code)
CAUSE
● BO has received a message which is not actually classified as a message. The details (ident
code) concern the contents of the message. These values are given in (Info1/Info2).
REMEDY
● Write down error message giving the complete error message and under what conditions the
error occurred. With the machine at standstill, reset the machine.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
66
702 BO: Mouse code not implemented (mouse code)
CAUSE
● BO has received an unknown message.
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
703 BO: CODE received unknown (code/state)
CAUSE
● BO has received unknown or unexpected message.
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
704 Text table could not be initialized at first attempt
CAUSE
● There is an error in the text table (text too long, for example)
REMEDY
● It is not necessary to stop operation. Please notify Siemens Service.
705 BO: Unknown element type in dialogue field (typ)
CAUSE
● Error in the data of the BO
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
706 BO: ID type unknown in menu (menuid_typ)
CAUSE
● Error in the data of the BO
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
707 CRDL 1 configured without mechanical centering
CAUSE
● Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
● Correct the configuration in the line computer for this station.