00191494-01.pdf - 第49页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 47 443 Coplan.: Measuring data buffer is fu ll CAUSE ● Mismeasurement: component out of focus or measuremen t interrupted by EME…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
46
431 Colinearity: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
432 Spacing: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
433 Position: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
47
443 Coplan.: Measuring data buffer is full
CAUSE
Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
447 Z-axis at IC head cannot be moved upwards
CAUSE
When the start button is pressed the Z-axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
Move Z-axis upwards manually; check Z-axis IC head.
449 IC head Z-axis does not reach placement/pick-up position
CAUSE
Z-axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
Inform Siemens Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z-axis does not reach 0 position
CAUSE
Z-axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
Inform Siemens Service; inspect the jamming; change zero point correction.
451 IC head sensor for Z-axis does not react
CAUSE
Top Bero of the Z-axis of the IC head defective; top Bero of the Z-axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
Check input top Bero (input is always 0); realign top Bero of the Z-axis of the IC head; change
zero point correction.
452 IC head sensor for Z-axis is not released at top
CAUSE
Top Bero of the Z-axis of the IC head defective.
REMEDY
Check input top Bero (input is always 1).
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
48
453 Component could not be placed
CAUSE
After placement by the IC head the component is still at the nozzle.
REMEDY
Vacuum circuit defective; forced air or vacuum cannot be switched off.
454 Component could not be placed. Warning!
CAUSE
The component could be recognized as placed by the IC head only after the second measure-
ment.
REMEDY
Check vacuum circuit; check forced air and vacuum of the IC head.
455 Component not on nozzle during placement
CAUSE
After placement by the IC head the component is still at the nozzle.
REMEDY
Vacuum circuit defective; forced air or vacuum cannot be switched off.
456 Component not on nozzle during placement. Warning!
CAUSE
The component could be recognized as placed by the IC head only after the second measure-
ment.
REMEDY
Check vacuum circuit; check forced air and vacuum of the IC head.
459 Coplan.: Memory for group description full
CAUSE
In the set-up there are too many components with coplanarity measurement.
REMEDY
Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
In the set-up there are too many components with coplanarity measurement.
REMEDY
Reduce set-up.
461 Programmed position of D-axis outside of travel range
CAUSE
Should not occur.
REMEDY
Inform Siemens Service.