Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 32 321 Undefined error number from CRDL (Error code 17H) CAUSE ● Hardware error at tester. REMEDY ● Reset station, if occurs rep…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
31
314 CRDL not initialized, test not possible
CAUSE
● Incorrect command sent to tester.
REMEDY
● If electrical testing is not possible, reset tester.
315 CRDL internal error (Error code 11H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
316 CRDL internal error (Error code 12H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
317 CRDL internal error (Error code 13H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
318 CRDL internal error (Error code 14H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
319 Format error of selected component in SMD data record (15H)
CAUSE
● Erroneous CRDL component description
REMEDY
● Check data record for CRDL test in the component description in the line computer and correct if
necessary.
320 Format error in measurement request (Error code 16H)
CAUSE
● Incorrect command sent to tester.
REMEDY
● If electrical testing is not possible, reset tester.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
32
321 Undefined error number from CRDL (Error code 17H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
322 CRDL internal error (Error code 18H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
323 Still no compensation values in CRDL (Error code 19H)
CAUSE
● Compensation not carried out.
REMEDY
● Carry out compensation with single functions.
325 Measure ranges exceeded (Error code 1BH)
CAUSE
● Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
● Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
33
329 Measured value outside tol. (Error code 1FH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
331 Measured value outside tol. (Error code 21H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
● Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
● Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.