00191494-01.pdf - 第34页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 32 321 Undefined error number from CRDL (Error code 17H) CAUSE ● Hardware error at tester. REMEDY ● Reset station, if occurs rep…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
31
314 CRDL not initialized, test not possible
CAUSE
Incorrect command sent to tester.
REMEDY
If electrical testing is not possible, reset tester.
315 CRDL internal error (Error code 11H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
316 CRDL internal error (Error code 12H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
317 CRDL internal error (Error code 13H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
318 CRDL internal error (Error code 14H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
319 Format error of selected component in SMD data record (15H)
CAUSE
Erroneous CRDL component description
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary.
320 Format error in measurement request (Error code 16H)
CAUSE
Incorrect command sent to tester.
REMEDY
If electrical testing is not possible, reset tester.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
32
321 Undefined error number from CRDL (Error code 17H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
322 CRDL internal error (Error code 18H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
323 Still no compensation values in CRDL (Error code 19H)
CAUSE
Compensation not carried out.
REMEDY
Carry out compensation with single functions.
325 Measure ranges exceeded (Error code 1BH)
CAUSE
Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
33
329 Measured value outside tol. (Error code 1FH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
331 Measured value outside tol. (Error code 21H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.