Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 94 902 OPT : No memory received CAUSE ● Software error in glue o ptimization: no more memory available REMEDY ● Files may be too…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
93
895 DP: Range limits in telegram exceeded
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
896 DP: String too long
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
897 DP: Glue identification lines not available
CAUSE
In aktuell.ma the incorrect glue name was specified
REMEDY
Correct the data in aktuell.ma
898 DP: VKL data not available
CAUSE
A glue name specified in aktuell.ma is not available *.VKL file
REMEDY
Correct aktuell.ma and *.VKL file
899 DP: INI data not available
CAUSE
A glue name specified in aktuell.ma is not available as *.INI file
REMEDY
Correct aktuell.ma and *.INI file
900 OPT: Error during data reception
CAUSE
Software error between data preparation and glue optimization
REMEDY
Cluster data should be corrected; reboot
901 OPT: Error during memory request
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
94
902 OPT: No memory received
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
903 OPT: Error during look
CAUSE
Software error in glue optimization
REMEDY
Reboot
904 OPT: No glueing position received
CAUSE
Glue optimization received the glueing number "zero"
REMEDY
Check data
905 Glueing size not possible with glue available
CAUSE
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
Glueing size is larger than 20
REMEDY
Check data
907 OPT: Glueing position outside of travel range
CAUSE
Optimization received a position outside the travel range
REMEDY
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
Board barcode has been sent to line computer; the line computer does not have this barcode in
its list
REMEDY
Wrong board fed in; something wrong with the list in the line computer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
95
909 DP: Glue type list KLL incorrectly loaded
CAUSE
Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
The job file is not consistent
REMEDY
Check the camera records in REAL.MA; check the job data (GF data) in the line computer.
911 OPT: Spacer in contact with glueing point
CAUSE
Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: Gantry ID error in small gantry mapping data
CAUSE
Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gan-
tries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
1005 Z-axis; GU1: Bero at top does not react
CAUSE
Z1-axis is not positioned high enough; Bero defective; Z1-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.