00191494-01.pdf - 第30页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 28 284 VS: A request is now being p rocessed CAUSE ● A request is being proc essed in the vision system. REMEDY ● If this error …

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
27
277 VS: Check sum error during data transmission
CAUSE
Communications error
REMEDY
If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data
in REAL.MA have too great a value.
REMEDY
Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
Memory problems in the ICOS.
REMEDY
Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
ICOS cannot accept any further model descriptions.
REMEDY
Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
Memory location problems in the ICOS.
REMEDY
Reset ICOS.
283 Incorrect Eprom version in MVS
CAUSE
The EPROM version in the MVS cannot be used with the station computer software. (Version dis-
played in the vision menu).
REMEDY
Replace the EPROM in the MVS.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
28
284 VS: A request is now being processed
CAUSE
A request is being processed in the vision system.
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
Hardware error
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
A hardware break was sent to the coplanarity module.
REMEDY
Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity
module.
288 Telegram to coplanarity has no STX
CAUSE
The first character sent to the coplanarity module is lost.
REMEDY
Check supply voltage; check jumper; repeat measurement.
292 Communication to vision system defective (Error code -11)
CAUSE
System error
REMEDY
Reset system.
293 Communication to vision system defective (Error code -10)
CAUSE
System error
REMEDY
Reset system.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
29
294 Communication to vision system defective (Error code -9)
CAUSE
System error
REMEDY
Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
System error
REMEDY
Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
System error
REMEDY
Reset system.
297 Communication to vision system defective (Error code -6)
CAUSE
System error
REMEDY
Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
System error
REMEDY
Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
System error
REMEDY
Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
Timeout during request to vision system (MVS / M10000).
REMEDY
Reset vision system; at M10000 check V24 connection between MC and M10000.