Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 79 797 BO: T ext line interrupted at type (character/i) CAUSE ● Contents of the text file are f aulty . REMEDY ● If the error oc…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
78
790 BO: Error while closing text configuration file
CAUSE
● System error: opened file can no longer be closed.
REMEDY
● Reset station.
791 BO: Error in ALOC 1. text pool (length 1000./1.)
CAUSE
● Not enough memory available to read in the text file.
REMEDY
● Reset station.
792 BO: Error while reading text file
CAUSE
● Erroneous text file.
REMEDY
● Check text file; check hard disk with CHKDSK.
793 BO: Error while closing text file
CAUSE
● System error: opened file can no longer be closed.
REMEDY
● Reset station.
794 BO: Incorrect text index (character/ith character)
CAUSE
● Contents of the text file faulty.
REMEDY
● If the error occurs again after error message 704, reset station. Text file faulty at the position ith
character.
795 BO: Text line interrupted at index (character/i)
CAUSE
● Contents of the text file faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
796 BO: Text line interrupted at length (character/i)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
79
797 BO: Text line interrupted at type (character/i)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
798 BO: Text line interrupted at name (character/i)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
799 BO: Unknown state while loading texts (state)
CAUSE
● System error while loading the texts.
REMEDY
● Reset station.
800 BO: Text too long (text index/actual length)
CAUSE
● A text is longer than permitted.
REMEDY
● If the error occurs again after error message 704, inform Siemens Service.
801 BO: Invalid length information (text index/ith char)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
802 BO: Postponement line full (ident/code)
CAUSE
● The operator interface is receiving too many jobs and cannot process these.
REMEDY
● Reset station.
803 BO: Insufficient memory for postponement (length)
CAUSE
● No memory available.
REMEDY
● Reset station.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
80
804 BO: POOL cannot be given back (length);
CAUSE
● A requested memory area can no longer be returned, system error.
REMEDY
● Reset station.
805 BO: Message cannot be sent (state/code)
CAUSE
● Error during system call "send" or not enough memory available.
REMEDY
● Reset station.
806 NF: unexpected input
CAUSE
● System error
REMEDY
● If possible, ignore
807 KLKONF: System error during initialization
CAUSE
● Software error in glueing configuration task
REMEDY
● Reboot
808 KLKONF: System error during memory request
CAUSE
● Software error in glueing configuration task during memory request
REMEDY
● Reboot
809 KLKONF: System error during give back memory
CAUSE
● Software error in glueing configuration task during give back of memory
REMEDY
● Reboot
810 KLKONF: System error during send message
CAUSE
● Software error in glueing configuration task during send message
REMEDY
● Reboot