Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 111 1 131 Z-axis error, GU1: incorrect acceleration CAUSE ● Invalid value in the machine d ata REMEDY ● Check the machine data 1…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
110
1124 Z-axis error, GU1: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1125 Z-axis error; GU2: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1126 Z-axis error, GU3: Reference error
CAUSE
Invalid reference point type in the machine data
REMEDY
Check machine data
1127 X-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1128 Y-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1129 xk-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1130 yk-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
111
1131 Z-axis error, GU1: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1132 Z-axis error; GU2: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1133 Z-axis error; GU3: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1134 X-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1135 Y-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1136 xk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1137 yk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
112
1138 Z-axis error, GU1: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1141 X-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1142 Y-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1143 xk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1144 yk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism