Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
43
397 Check sum error in communication with table
CAUSE
Transmission error during transmission of machine controller with component table.
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.
398 Coplan.: Row not available
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
399 Program loss of table or trolley control
CAUSE
Battery reserve in the component table is not working.
REMEDY
Fit new battery to component table.
400 RAM of trolley control defective
CAUSE
Hardware error in the component table
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.
401 New nozzle configuration is required
CAUSE
New cluster with different nozzle configuration
REMEDY
If no nozzle changer is present, apply new nozzle configuration manually to placement head.
402 Pulse is not okay
CAUSE
Connection of pulse output to pulse input defective.
REMEDY
Check pulse output and pulse input
403 Coplan.: Too many pins measured
CAUSE
Measurement erroneous or incorrect component.
REMEDY
Repeat measurement.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
44
404 Fault during vacuum measuring in reject position
CAUSE
Nozzle worn.
REMEDY
Fit new nozzle.
405 Fault during vacuum measuring in reject position
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
406 Axis does not find the correct zero pulse
CAUSE
Measurement head incorrectly set
REMEDY
Check zero pulse at the measurement head (moving scale) of the longitudinal measurement
system. Adjust or replace measurement head.
407 Communication with table disturbed
CAUSE
Timeout during request to the component table controller.
REMEDY
Check cabling.
408 Table has received unknown command
CAUSE
Obsolete TISCH.HEX file.
REMEDY
Update TISCH.HEX file.
410 Telegram to coplanarity too long
CAUSE
Package form description of the component includes too much information.
REMEDY
Check and respecify package form data; the package form is too large and cannot be processed.
423 Position: Evaluation not possible
CAUSE
Component is not positioned properly at the nozzle, or is missing; optical image inadequate.
REMEDY
Change the illumination values and / or the LUT.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
45
424 Dimension: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
425 No. of pins: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
426 Colinearity: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
427 Spacing: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
428 Position: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
429 Dimension: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
430 No. of pins: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.