00191494-01.pdf - 第21页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 19 214 Check sum error of answer from c oplanarity CAUSE ● Error in the response from cop lanarity . REMEDY ● Check the supply v…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
18
207 Fault in placement stat. during vac. meas.
CAUSE
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing;
component was not picked up properly; vacuum in the holding circuit too low; vacuum board
defective.
REMEDY
Fit new nozzle; calibration of the motor control board; check component feed, call Siemens Ser-
vice.
208 End position BERO of centering station not being actuated
CAUSE
End position Bero defective or incorrectly set; recuperator spring of the centering station worn
out.
REMEDY
Fit new Bero, adjust; maintain centering station.
209 Counting error X-axis
CAUSE
Scales dirty (incremental encoder).
REMEDY
Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
Distance between Bero and actuator flag too great; Bero defective
REMEDY
Correct distance to actuator flag; fit new Bero.
211 Counting error Y-axis
CAUSE
Scales dirty (incremental encoder).
REMEDY
Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
O-ring on the sealing piston damaged.
REMEDY
Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
Coplanarity module not plugged in
REMEDY
Plug in module
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
19
214 Check sum error of answer from coplanarity
CAUSE
Error in the response from coplanarity.
REMEDY
Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S-axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
216 Position control of X-axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
217 Position control of Y-axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
The first character of the answer from coplanarity is lost.
REMEDY
Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
Too many measurement data for one component
REMEDY
Inform Siemens Service.
220 Coplanarity cannot execute command
CAUSE
Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
Switch machine off and back on; respecify set-up; check package form data.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
20
221 Programmed position of X-axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
222 Programmed position of Y-axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
226 Vacuum of pick-up circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
228 Interface signals to the preceding station incorrect
CAUSE
Interface line not connected; cable defective; interface boards defective.
REMEDY
Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
PCB board jamming; sensor defective.
REMEDY
Correct the jamming; fit new sensor.