Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 118 1 178 Actual temperature does not reach desired temp. CAUSE ● Glueing parameter con troller did not reach the des ired tempe…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
117
1171 Error during Send
INI data
to GU
CAUSE
An error occurred while .ini data was being sent to the GU
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1172 GU: Error during Send process data
CAUSE
An error occurred while process data was being sent to the GU.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1173 GU: Error during Receive process data
CAUSE
An error occurred while process data was being received by the GU.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1174 WARNING: Fill cartridge before next PCB
CAUSE
Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
This was preceded by error 1174 and the cartridge was still not changed
REMEDY
Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
One of the cleaning conditions has occurred. Not an error
REMEDY
The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
Software error
REMEDY
Siemens Service should be notified
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
118
1178 Actual temperature does not reach desired temp.
CAUSE
Glueing parameter controller did not reach the desired temperature
REMEDY
Hardware should be checked
1179 Glue cleaning pad paper finished
CAUSE
Glue cleaning pad finished
REMEDY
Insert new paper
1180 Z-axis, GU1: Bero not activated during upward movement
CAUSE
Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1181 Z-axis, GU2: Bero not activated during upward movement
CAUSE
Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: Bero not activated during upward movement
CAUSE
Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: Bero not released when axis at bottom
CAUSE
Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: Bero not released when axis at bottom
CAUSE
Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
119
1185 Z-axis, GU3: Bero not released when axis at bottom
CAUSE
Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
The venting valve (actuation) is defective
REMEDY
Check the valve and hoses
1188 Glue spot check: error during meas. description generation
CAUSE
Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
Check data
1189 Glue spot check: error during measurement description loading
CAUSE
Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
1191 Glue spot check: measurements start error
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system