Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 118 1 178 Actual temperature does not reach desired temp. CAUSE ● Glueing parameter con troller did not reach the des ired tempe…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
117
1171 Error during Send
INI data
to GU
CAUSE
● An error occurred while .ini data was being sent to the GU
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1172 GU: Error during Send process data
CAUSE
● An error occurred while process data was being sent to the GU.
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1173 GU: Error during Receive process data
CAUSE
● An error occurred while process data was being received by the GU.
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1174 WARNING: Fill cartridge before next PCB
CAUSE
● Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
● Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
● This was preceded by error 1174 and the cartridge was still not changed
REMEDY
● Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
● One of the cleaning conditions has occurred. Not an error
REMEDY
● The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
● Software error
REMEDY
● Siemens Service should be notified
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
118
1178 Actual temperature does not reach desired temp.
CAUSE
● Glueing parameter controller did not reach the desired temperature
REMEDY
● Hardware should be checked
1179 Glue cleaning pad paper finished
CAUSE
● Glue cleaning pad finished
REMEDY
● Insert new paper
1180 Z-axis, GU1: Bero not activated during upward movement
CAUSE
● Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
1181 Z-axis, GU2: Bero not activated during upward movement
CAUSE
● Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: Bero not activated during upward movement
CAUSE
● Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: Bero not released when axis at bottom
CAUSE
● Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: Bero not released when axis at bottom
CAUSE
● Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
119
1185 Z-axis, GU3: Bero not released when axis at bottom
CAUSE
● Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
● The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
● Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
● The venting valve (actuation) is defective
REMEDY
● Check the valve and hoses
1188 Glue spot check: error during meas. description generation
CAUSE
● Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
● Check data
1189 Glue spot check: error during measurement description loading
CAUSE
● Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
● Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
● Transmission error with MVS vision system
REMEDY
● Check vision system
1191 Glue spot check: measurements start error
CAUSE
● Transmission error with MVS vision system
REMEDY
● Check vision system