00191494-01.pdf - 第106页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 104 1077 Z-axis error; GU3: deactivate d CAUSE ● Axis has been deactiva ted at the axis board (servo ) REMEDY ● Switch the axis …

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
103
1056 Z-axis; GU3: BERO for position monitoring off
CAUSE
When the gantry moves the Z3-axis is not at the top; alignment of the Bero is faulty; Bero is defec-
tive
axis is jamming; motor, controller, servo defective
REMEDY
Inspect and if necessary repair or replace the components just mentioned
1071 X-axis error: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1072 Y-axis error: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1073 xk-axis error: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1074 yk-axis error: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1075 Z-axis error; GU1: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1076 Z-axis error; GU2: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
104
1077 Z-axis error; GU3: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1085 X-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1086 Y-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1087 xk-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1088 yk-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1089 Z-axis error; GU1: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
105
1090 Z-axis error; GU2: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1091 Z-axis error; GU3: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1092 X-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1093 Y-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1094 xk-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1095 yk-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again