Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 45 424 Dimension: Evaluation not possible CAUSE ● No component at the nozzle ; component outside tolera nce; not enough image in…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
44
404 Fault during vacuum measuring in reject position
CAUSE
Nozzle worn.
REMEDY
Fit new nozzle.
405 Fault during vacuum measuring in reject position
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
406 Axis does not find the correct zero pulse
CAUSE
Measurement head incorrectly set
REMEDY
Check zero pulse at the measurement head (moving scale) of the longitudinal measurement
system. Adjust or replace measurement head.
407 Communication with table disturbed
CAUSE
Timeout during request to the component table controller.
REMEDY
Check cabling.
408 Table has received unknown command
CAUSE
Obsolete TISCH.HEX file.
REMEDY
Update TISCH.HEX file.
410 Telegram to coplanarity too long
CAUSE
Package form description of the component includes too much information.
REMEDY
Check and respecify package form data; the package form is too large and cannot be processed.
423 Position: Evaluation not possible
CAUSE
Component is not positioned properly at the nozzle, or is missing; optical image inadequate.
REMEDY
Change the illumination values and / or the LUT.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
45
424 Dimension: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
425 No. of pins: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
426 Colinearity: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
427 Spacing: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
428 Position: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
429 Dimension: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
430 No. of pins: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
46
431 Colinearity: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
432 Spacing: no result
CAUSE
Due to a preceding error no result is issued by the vision system.
REMEDY
See preceding error.
433 Position: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.