00191494-01.pdf - 第52页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 50 469 Component outside of position al tolerance CAUSE ● Pick-up not accurate en ough; positional tolerance s entered in the pa…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
49
462 Programmed position of Z-axis outside of travel range
CAUSE
Head height, nozzle length erroneous.
REMEDY
Correct head height, nozzle length.
463 IC head D-axis does not reach desired position
CAUSE
Motor defective; clamping actuated.
REMEDY
Fit new motor; release clamping and check.
464 IC head Z-axis does not reach desired position
CAUSE
Motor defective; Z-axis jamming; clamping actuated.
REMEDY
Fit new motor; check Z-axis; release clamping and check.
465 IC head D-axis disabled
CAUSE
D-axis switched off at the axis controller switch.
REMEDY
Switch on D-axis at the axis controller.
466 IC head Z-axis disabled
CAUSE
Z-axis switched off at the axis controller switch.
REMEDY
Switch on Z-axis at the axis controller.
467 Gantry distance insufficient. Protective system reacted
CAUSE
Gantries have been moved too close together.
REMEDY
Switch machine off and back on.
468 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too
small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
50
469 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too
small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.
471 Component width outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.
472 VS: Pointer to text table not initialized
CAUSE
Component is not in focus during coplanarity measurement.
REMEDY
Check the focussing during coplanarity measurement; check the IC head Z-axis clamping
473 Temporary drop in pressure
CAUSE
The compressed air failed during the placement process, the current PCB board is aborted.
REMEDY
Check compressed air feed; check compressed air sensor.
474 Second gantry in travel range
CAUSE
While teaching the fiducials (80S), the operator moved the gantries towards each other.
REMEDY
Move the second gantry out of the travel range of the first gantry.
475 Communication with wafflepack changer faulty
CAUSE
Interface line to the wafflepack changer defective or not correctly connected; power supply to the
wafflepack changer defective.
REMEDY
Check interface cable; check power supply.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
51
476 IC head vacuum of pick-up circle not in valid range
CAUSE
Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle erro-
neous.
REMEDY
Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open
nozzle.
477 Nozzle available on IC head
CAUSE
According to the software configuration there is already a nozzle at the head. This message
appears when an attempt is still made to start the pick-up procedure.
REMEDY
If there does not happen to be a nozzle at the head, set up the nozzle specified by the configura-
tion by hand.
478 Deviation position Z-axis at nozzle changer IC head
CAUSE
Z-axis has gone beyond or not reached its desired position (MA data); the Z-axis is jamming
the nozzle is already at the head at pick-up.
REMEDY
Check the x, y and z positions; make sure the axis can move freely.
479 Deviation rotation D-axis pick up nozzle IC head
CAUSE
The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
Remeasurement and inputting into MA data.
480 Deviation rotation D-axis return nozzle IC head
CAUSE
The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
Remeasurement and inputting into MA data.
481 Nozzle not available at nozzle changer IC head
CAUSE
A nozzle is being requested which is not in the nozzle changer.
REMEDY
If request by machine: check set-up.
If input by operator: correct incorrect input.