00191494-01.pdf - 第63页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 61 553 Coplan.: Software error during syst em call RIO CAUSE ● Communication with the copla narity module has been inte rrupted …

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
60
546 WPC: Error in saved set-up.
CAUSE
At pick-up of the component division number not in the set-up; checksum of the set-up erroneous.
REMEDY
Reboot and inform Siemens Service.
547 WPC: One tray of saved set-up missing
CAUSE
No tray present when changing levels; the "Tray in magazine" Bero is defective.
REMEDY
Fit new "Tray in magazine" Bero.
548 WPC: When returning tray, level occupied
CAUSE
Tray placed in travel range of the feed axis (when feed axis moved out);
the "Tray in magazine" Bero is defective.
REMEDY
Remove tray; fit new "Tray in magazine" Bero.
549 WPC: Tray has been taken out.
CAUSE
Ready tray was removed; the "Tray ready" Bero is defective.
REMEDY
Re-insert tray; fit new "Tray ready" Bero.
550 WPC: Take-over position already occupied
CAUSE
A tray already occupied the take-over position; the "Tray ready" Bero is defective.
REMEDY
Remove tray; fit new "Tray ready" Bero.
551 WPC: Tray in incorrect position or protection not closed properly.
CAUSE
Guard not correctly closed; tray positioned incorrectly; the "Lock against rotation " Bero is defec-
tive.
REMEDY
Close guard correctly; insert tray correctly; fit new "Lock against rotation" Bero.
552 WPC: Feed axis has touched protection.
CAUSE
The "Lock against rotation" Bero is defective; guard was opened during change procedure; tray
inserted incorrectly and driven against the guard.
REMEDY
Close guard; fit new "Lock against rotation" Bero; insert tray correctly.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
61
553 Coplan.: Software error during system call RIO
CAUSE
Communication with the coplanarity module has been interrupted
REMEDY
Check the V-24 interface cable; check the jumper setting of the coplanarity module.
554 Communication between SR and MC interrupted
CAUSE
Hardware fault in a module (M18, M34) or a wiring fault.
REMEDY
Replace modules; check the wiring at the back of the control unit.
555 IC head nozzle changer option not set
CAUSE
The nozzle-changer was called without this option being set in the line computer.
REMEDY
Configure the nozzle-changer in the line computer.
556 Nozzle type not available
CAUSE
During nozzle changing or pick-up a nozzle type was demanded which lies outside the valid
range.
REMEDY
Check the cluster and set-up.
557 Nozzle type not in IC-head nozzle changer set-up
CAUSE
The nozzle type required was not included in the nozzle-changer set-up
REMEDY
Modify nozzle-changer set-up.
558 Error during MVS initialization via HS3L
CAUSE
Wiring of HS3L interface faulty; MVS card not inserted correctly in control unit.
REMEDY
Check HS3L wiring; check seating of the MVS card.
559 Data error in MC: optical centering indices incorrect
CAUSE
The job data are inconsistent.
REMEDY
Check the camera records in the REAL.MA file; check the job data (GF data) in the line computer.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
62
560 Error during execution of SP nozzle head check
CAUSE
Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
Notify Siemens Service.
561 Modify SP head nozzle-changer
CAUSE
The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line compu-
ter) erroneous; incorrect sensor system type input at line computer
REMEDY
Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
565 Error during loading of fiducials into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version