Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 86 846 DP: Loading of pack. form or fid. data not successful CAUSE ● Error while reading and loading the package form o r fiduci…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
85
839 DP: Cannot open file
CAUSE
An error occurred while the file was being read
REMEDY
Hard disk and file should be checked
840 DP: Cannot write file
CAUSE
While the file was being written an error occurred
REMEDY
Hard disk, file and file attribute (Read/Write) should be checked
841 DP: Cannot log on drive
CAUSE
Hardware error
REMEDY
Hardware and hard disk should be checked
842 DP: Cannot log off drive
CAUSE
Hardware error
REMEDY
Hardware and hard disk should be checked
843 DP: Cannot open fiducial file
CAUSE
Error while reading the fiducial file
REMEDY
Hard disk and file should be checked
844 DP: Cannot open fiducial list file
CAUSE
Error while reading the fiducial list file
REMEDY
Hard disk and file should be checked
845 DP: Head in local files wrong or incomplete
CAUSE
Incorrect head entered in machine data
REMEDY
Check machine data
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
86
846 DP: Loading of pack. form or fid. data not successful
CAUSE
Error while reading and loading the package form or fiducial data.
REMEDY
Data of package form and fiducial file should be checked
847 DP: Error in list for passpoint sets and fiducials
CAUSE
Error in real.ma and fiducial file
REMEDY
Data in real and fiducial files should be checked
848 File AKTUELL.MA cannot be stored
CAUSE
Changing and rewriting aktuell.ma is not possible
REMEDY
Hard disk should be checked
849 VKL file cannot be stored
CAUSE
Not possible to rewrite the *.VKL file
REMEDY
Hard disk should be checked
850 Process data cannot be stored
CAUSE
Not possible to rewrite the glueing head process switches (C:\TMP\VL_PDAT.K1/2/3)
REMEDY
Hard disk should be checked
851 Process data cannot be read
CAUSE
1. At first time still no process data found
2. Error occurred during read
REMEDY
To 1. Not an error
To 2. File and hard disk should be checked
852 Data preparation: Cannot save current MA data
CAUSE
Not possible to change or rewrite the aktuell.ma file
REMEDY
Hard disk should be checked
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
87
853 MA data: Invalid fiducial number for system fiducial
CAUSE
System fiducials must lie within the range 250 to 255
REMEDY
Correct the fiducial data in the MA data or set-up.
854 MA data: Error in sensor system types
CAUSE
Different sensor system types, or invalid for machine, in real.ma and ideal.ma
quoted (line computer telegram).
REMEDY
Make data consistent.
855 MA data: Missing height offset
CAUSE
Height offset not entered in real.ma.
REMEDY
Measure height offset and enter in real.ma.
856 MA data: Too many zero point fiducials
CAUSE
More than one zero point fiducial has been entered in ideal.ma.
REMEDY
Enter one fiducial only.
857 MA data: Mapping plate irregular
CAUSE
Irregular mapping plate is not supported.
REMEDY
Raster.px file should be checked; if necessary, remeasure
858 MA data: Error in nozzle type/vacuum correction values
CAUSE
For nozzle type in aktuell.ma no vacuum correction values can be found.
REMEDY
Enter valid nozzle type in aktuell.ma.
859 MA data: Invalid compartment at nozzle changer
CAUSE
An invalid compartment number has been entered in aktuell.ma or real.ma
REMEDY
Make the data consistent again.