Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 29 294 Communication to vision system de fective (Error code -9) CAUSE ● System error REMEDY ● Reset system. 295 Communication t…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
28
284 VS: A request is now being processed
CAUSE
● A request is being processed in the vision system.
REMEDY
● If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
● The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
● Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
● Hardware error
REMEDY
● If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
● A hardware break was sent to the coplanarity module.
REMEDY
● Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity
module.
288 Telegram to coplanarity has no STX
CAUSE
● The first character sent to the coplanarity module is lost.
REMEDY
● Check supply voltage; check jumper; repeat measurement.
292 Communication to vision system defective (Error code -11)
CAUSE
● System error
REMEDY
● Reset system.
293 Communication to vision system defective (Error code -10)
CAUSE
● System error
REMEDY
● Reset system.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
29
294 Communication to vision system defective (Error code -9)
CAUSE
● System error
REMEDY
● Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
● System error
REMEDY
● Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
● System error
REMEDY
● Reset system.
297 Communication to vision system defective (Error code -6)
CAUSE
● System error
REMEDY
● Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
● System error
REMEDY
● Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
● System error
REMEDY
● Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
● Timeout during request to vision system (MVS / M10000).
REMEDY
● Reset vision system; at M10000 check V24 connection between MC and M10000.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
30
301 Communication to vision system defective (Error code -2)
CAUSE
● System error
REMEDY
● Reset system.
302 Communication to vision system defective (Error code -1)
CAUSE
● System error
REMEDY
● Reset system.
303 Communication to vision system defective (Error code 0)
CAUSE
● System error
REMEDY
● Reset system.
304 Communication to vision system defective (Error code 1)
CAUSE
● System error
REMEDY
● Reset system.
311 Undefined error number from vision system (Error code 2)
CAUSE
● System error
REMEDY
● Reset system.
312 Coplan.: Component description has too many groups
CAUSE
● Package form data erroneous.
REMEDY
● Check package form data and respecify set-up.
313 Coplan.: Component number invalid
CAUSE
● No component description exists for the component to be measured
REMEDY
● Check set-up and respecify.