00191494-01.pdf - 第31页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 29 294 Communication to vision system de fective (Error code -9) CAUSE ● System error REMEDY ● Reset system. 295 Communication t…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
28
284 VS: A request is now being processed
CAUSE
A request is being processed in the vision system.
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
Hardware error
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
A hardware break was sent to the coplanarity module.
REMEDY
Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity
module.
288 Telegram to coplanarity has no STX
CAUSE
The first character sent to the coplanarity module is lost.
REMEDY
Check supply voltage; check jumper; repeat measurement.
292 Communication to vision system defective (Error code -11)
CAUSE
System error
REMEDY
Reset system.
293 Communication to vision system defective (Error code -10)
CAUSE
System error
REMEDY
Reset system.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
29
294 Communication to vision system defective (Error code -9)
CAUSE
System error
REMEDY
Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
System error
REMEDY
Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
System error
REMEDY
Reset system.
297 Communication to vision system defective (Error code -6)
CAUSE
System error
REMEDY
Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
System error
REMEDY
Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
System error
REMEDY
Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
Timeout during request to vision system (MVS / M10000).
REMEDY
Reset vision system; at M10000 check V24 connection between MC and M10000.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
30
301 Communication to vision system defective (Error code -2)
CAUSE
System error
REMEDY
Reset system.
302 Communication to vision system defective (Error code -1)
CAUSE
System error
REMEDY
Reset system.
303 Communication to vision system defective (Error code 0)
CAUSE
System error
REMEDY
Reset system.
304 Communication to vision system defective (Error code 1)
CAUSE
System error
REMEDY
Reset system.
311 Undefined error number from vision system (Error code 2)
CAUSE
System error
REMEDY
Reset system.
312 Coplan.: Component description has too many groups
CAUSE
Package form data erroneous.
REMEDY
Check package form data and respecify set-up.
313 Coplan.: Component number invalid
CAUSE
No component description exists for the component to be measured
REMEDY
Check set-up and respecify.