00191494-01.pdf - 第115页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 113 1 145 Z-axis error, GU1: I-square CAUSE ● R.m.s. current of the servo-am plifier exceeded; motor over loaded; mechanically s…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
112
1138 Z-axis error, GU1: Reference point not found
CAUSE
● Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
● Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
● Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
● Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
● Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
● Repeat reference run; check incremental pulses; if necessary, replace motor unit
1141 X-axis error: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
1142 Y-axis error: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
1143 xk-axis error: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
1144 yk-axis error: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
113
1145 Z-axis error, GU1: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
1146 Z-axis error; GU2: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
1147 Z-axis error; GU3: I-square
CAUSE
● R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
● Motor current should be checked; carry out maintenance on mechanism
1148 GU does not execute command
CAUSE
● When transmitting to the glueing unit it does not send an acknowledgement; V24 connection
interrupted; control board GU defective
REMEDY
● V24 connection should be checked; control board GU should be repaired
1149 GU does not send data
CAUSE
● When data is requested from the GU, it does not send any data
REMEDY
● Hardware of MC-GU should be checked; V24 connection should be checked; carry out mainte-
nance on control board GU
1150 GU: Receiving buffer too small
CAUSE
● Record length when sending or receiving to or from the GU exceeds the sending / receiving buffer
Software error - incompatible versions of MC and GU
REMEDY
● Check versions
1151 GU: Checksum error
CAUSE
● When sending to the GU a negative acknowledgement is received from the GU
REMEDY
● Software error. Siemens Service should be notified
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
114
1152 GU: Checksum error in message from head
CAUSE
● When receiving a message from the GU the checksum is not correct.
REMEDY
● Software error of the GU. Siemens Service should be notified
1153 GU does not know command
CAUSE
● The MC sends a command to the GU which is not defined
REMEDY
● Incompatible versions of MC and GU
1154 GU is indicating error during glueing
CAUSE
● Head not initialized: no pressure build-up; no venting; no pressure.
REMEDY
● Check hoses, valves; inspect for leaks
1155 GU does not know pressure range
CAUSE
● The pressure specified in the data command is inconsistent with the head file ( .ini),
*.vkl and *.ini file are not consistent. Software error
REMEDY
● Check vkl and ini files
1156 RAM error in GU
CAUSE
● During initialization of the GU the internal RAM memory is checked. If there is a fault this will be
reported at the first glueing action
REMEDY
● Hardware GU should be checked/replaced
1157 GU: incorrect glueing command
CAUSE
● The MC has sent a command to the GU which is not defined
REMEDY
● MC/GU commands should be checked
1158 GU: incorrect record number during Send
CAUSE
● When *.ini or process data were sent from MC to GU the record number was not correct
Software error or corrupt .ini or process data files.
REMEDY
● .ini and process data files should be checked.