00191494-01.pdf - 第115页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 113 1 145 Z-axis error, GU1: I-square CAUSE ● R.m.s. current of the servo-am plifier exceeded; motor over loaded; mechanically s…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
112
1138 Z-axis error, GU1: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1141 X-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1142 Y-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1143 xk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1144 yk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
113
1145 Z-axis error, GU1: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1146 Z-axis error; GU2: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1147 Z-axis error; GU3: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1148 GU does not execute command
CAUSE
When transmitting to the glueing unit it does not send an acknowledgement; V24 connection
interrupted; control board GU defective
REMEDY
V24 connection should be checked; control board GU should be repaired
1149 GU does not send data
CAUSE
When data is requested from the GU, it does not send any data
REMEDY
Hardware of MC-GU should be checked; V24 connection should be checked; carry out mainte-
nance on control board GU
1150 GU: Receiving buffer too small
CAUSE
Record length when sending or receiving to or from the GU exceeds the sending / receiving buffer
Software error - incompatible versions of MC and GU
REMEDY
Check versions
1151 GU: Checksum error
CAUSE
When sending to the GU a negative acknowledgement is received from the GU
REMEDY
Software error. Siemens Service should be notified
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
114
1152 GU: Checksum error in message from head
CAUSE
When receiving a message from the GU the checksum is not correct.
REMEDY
Software error of the GU. Siemens Service should be notified
1153 GU does not know command
CAUSE
The MC sends a command to the GU which is not defined
REMEDY
Incompatible versions of MC and GU
1154 GU is indicating error during glueing
CAUSE
Head not initialized: no pressure build-up; no venting; no pressure.
REMEDY
Check hoses, valves; inspect for leaks
1155 GU does not know pressure range
CAUSE
The pressure specified in the data command is inconsistent with the head file ( .ini),
*.vkl and *.ini file are not consistent. Software error
REMEDY
Check vkl and ini files
1156 RAM error in GU
CAUSE
During initialization of the GU the internal RAM memory is checked. If there is a fault this will be
reported at the first glueing action
REMEDY
Hardware GU should be checked/replaced
1157 GU: incorrect glueing command
CAUSE
The MC has sent a command to the GU which is not defined
REMEDY
MC/GU commands should be checked
1158 GU: incorrect record number during Send
CAUSE
When *.ini or process data were sent from MC to GU the record number was not correct
Software error or corrupt .ini or process data files.
REMEDY
.ini and process data files should be checked.